Maintenance

Veriflo valves are packless and do not require packing adjustment. Do not loosen 

or remove the clamp nut. A valve should be checked periodically for proper and 

safe operation. A valve should also be checked after cylinder changes or system 

maintenance. The user is solely responsible for determining the frequency of 

maintenance based on the application, that the recommended checks can be safely 

performed, and that the recommended checks are adequate to ensure proper and safe 

operation of the user’s system. A valve that does not comply with the recommended 

checks or malfunctions in any manner must be immediately removed from the service. 

Do not attempt to repair the valve.

• 

Check for valve seat leak. With the valve closed, there should be no leak across 

the valve seat. Leak test methods should be appropriate for the system leak 

integrity requirements.

• 

Check for leaks to atmosphere. With the valve open, there should be no leaks 

to atmosphere. Leak test methods should be appropriate for the system leak 

integrity requirements. 

Removing a valve from service: 

 Follow your system safety and maintenance 

procedures when removing a valve from service. Before removing a valve, the user 

must:

• 

Isolate the valve from all pressure sources upstream and downstream of the 

valve by closing the appropriate valves.

• 

Lockout valves and other system equipment needed to isolate pressure sources.

• 

Properly purge hazardous gases from the valve. 

• 

Vent all pressure in the valve. The valve should be open to ensure pressure is not 

trapped in the valve.

!

IMPROPER REPAIR OR SERVICING OF THIS PRODUCT CAN CAUSE DEATH, PERSONAL 

INJURY AND PROPERTY DAMAGE.

Veriflo Division products must pass rigid acceptance tests before leaving the factory. 

All repairs and servicing of this product must only be performed by factory certified 

personnel and tested for operation and leakage. Veriflo Division cannot assume 

responsibility for the performance or safety of a customer repaired or serviced product 

or for any damages resulting from failure of a customer repaired or serviced product or 

otherwise altered product.

WARNING:

Содержание 930 Series

Страница 1: ...n Veriflo Division 250 Canal Blvd Richmond California 94804 phone 510 235 9590 vfo quotes support parker com vfo support support parker com www parker com veriflo Mobile App m parker com veriflo Insta...

Страница 2: ...when using oxygen A serious risk of ignition fire and explosion exists Do not use a valve or operate a system if there is evidence of contamination e g debris particles oils lubricants grease etc Do n...

Страница 3: ...hould not be used Step 3 The fluid supplied to the valve must be clean Contamination can damage the valve s seat and cause a leak Step 4 Inlet and outlet connections may be identified by an arrow mark...

Страница 4: ...e counterclockwise until the stop is reached To close the valve Turn the handle clockwise until the valve is fully closed Toggle Valves To open the valve Place the lever in the vertical position To cl...

Страница 5: ...0 psig to the actuator port To close the valve Vent the pressure to the actuator to 0 psig Air Operated Valves Normally Open To open the valve Vent the pressure to the actuator to 0 psig To close the...

Страница 6: ...phere Leak test methods should be appropriate for the system leak integrity requirements Removing a valve from service Follow your system safety and maintenance procedures when removing a valve from s...

Страница 7: ...details on specific product and packaging materials contact the factory at vfo support support parker com 930AOPLPNC ACTUATOR CAP ALUMINUM UNS A96061 ANODIZED O RING FLUOROCARBON FLUORINATED GREASE SP...

Страница 8: ...LitPN 25000170 Date of Issue 2 2023 2023 Parker Hannifin Corporation Veriflo...