See Safety Guide (pn: 25000194) for more information.  Safety Guide available at 

www.parker.com/veriflo

WARNING:

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THIS PRODUCT 

CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from the Veriflo Division of Parker Hannifin Corporation, 

its subsidiaries and authorized distributors provides product and/or system options for further 

investigation by users having technical expertise. It is important that you analyze all aspects of 

your application, including consequences of any failure and review the information concerning 

the product or system in the current product catalog. Due to the variety of operating conditions 

and applications for these products and systems, the user, through its own analysis and testing, 

is solely responsible for making the final selection of the products and systems and assuring that 

all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, 

designs, availability and pricing, are subject to change by Veriflo Division, Parker Hannifin

Corporation and its subsidiaries at any time without notice.

OXYGEN SERVICE

The user is solely responsible for selecting the valve and specifying materials to be used

in oxygen service. Extreme caution must be taken when using oxygen. A serious risk of

ignition, fire, and explosion exists

• 

Do not use a valve or operate a system if there is evidence of contamination (e.g. debris, 

particles, oils, lubricants, grease, etc.);

• 

Do not interchange valves, components, or accessories with those that have been used in 

other types of gas service;

• 

Always open a valve slowly to avoid heating from adiabatic compression. 

 

 

Fast opening valves should not be used.

!

WARNING:

• 

Users must be trained and equipped for the handling, use and servicing of high-pressure fluids 

and systems.

• 

Users must contact their gas or liquid supplier for specific safety precautions and instructions.

• 

Always wear appropriate protective clothing including approved safety glasses, gloves, 

aprons, etc.

• 

Follow all applicable safety and maintenance procedures.

• 

Obey local, government and agency codes and regulations.

• 

Do not exceed the maximum inlet and outlet pressures of the product.

• 

Do not exceed the maximum operating pressure of pressure gauges, connections or other 

accessories provided with the product. Note that the maximum operating pressure of an 

accessory may be less than or greater than the maximum inlet pressure marked on the 

product.

• 

Operate within the temperature limits and other conditions specified for the product.

• 

Venting fluids and gases can be dangerous. Vent to a safe environment, away from 

employees. Ensure adequate ventilation to prevent suffocation.

• 

Questions regarding the installation, operation, and maintenance of a Veriflo product should 

be directed to (510) 235-9590 in the U.S. or visit our web site.

SAFETY PRECAUTIONS

!

Содержание 930 Series

Страница 1: ...n Veriflo Division 250 Canal Blvd Richmond California 94804 phone 510 235 9590 vfo quotes support parker com vfo support support parker com www parker com veriflo Mobile App m parker com veriflo Insta...

Страница 2: ...when using oxygen A serious risk of ignition fire and explosion exists Do not use a valve or operate a system if there is evidence of contamination e g debris particles oils lubricants grease etc Do n...

Страница 3: ...hould not be used Step 3 The fluid supplied to the valve must be clean Contamination can damage the valve s seat and cause a leak Step 4 Inlet and outlet connections may be identified by an arrow mark...

Страница 4: ...e counterclockwise until the stop is reached To close the valve Turn the handle clockwise until the valve is fully closed Toggle Valves To open the valve Place the lever in the vertical position To cl...

Страница 5: ...0 psig to the actuator port To close the valve Vent the pressure to the actuator to 0 psig Air Operated Valves Normally Open To open the valve Vent the pressure to the actuator to 0 psig To close the...

Страница 6: ...phere Leak test methods should be appropriate for the system leak integrity requirements Removing a valve from service Follow your system safety and maintenance procedures when removing a valve from s...

Страница 7: ...details on specific product and packaging materials contact the factory at vfo support support parker com 930AOPLPNC ACTUATOR CAP ALUMINUM UNS A96061 ANODIZED O RING FLUOROCARBON FLUORINATED GREASE SP...

Страница 8: ...LitPN 25000170 Date of Issue 2 2023 2023 Parker Hannifin Corporation Veriflo...