![Parker 690+ series Скачать руководство пользователя страница 240](http://html.mh-extra.com/html/parker/690-series/690-series_product-manual_755642240.webp)
Application Macros
5-30
690+ Series Frequency Inverter
Analog Input 1
–
VALUE
[ 16]
–
0.00 %
–
BREAK
[ 18]
–
FALSE
100.00 %
–
[ 14] SCALE
–
0.00 %
–
[ 15] OFFSET
–
0..+10 V
–
[ 13] TYPE
–
FALSE
–
[ 12] BREAK ENABLE
–
0.00 %
–
[ 17] BREAK VALUE
–
Analog Input 2
–
VALUE
[ 25]
–
0.00 %
–
BREAK
[ 27]
–
FALSE
100.00 %
–
[ 23] SCALE
–
0.00 %
–
[ 24] OFFSET
–
0..+10 V
–
[ 22] TYPE
–
FALSE
–
[ 21] BREAK ENABLE
–
0.00 %
–
[ 26] BREAK VALUE
–
Analog Input 3
–
VALUE
[715]
–
0.00 %
–
BREAK
[717]
–
FALSE
100.00 %
–
[713] SCALE
–
0.00 %
–
[714] OFFSET
–
0..+10 V
–
[712] TYPE
–
FALSE
–
[711] BREAK ENABLE
–
0.00 %
–
[716] BREAK VALUE
–
Analog Input 4
–
VALUE [722]
–
0.00 %
–
BREAK [724]
–
FALSE
100.00 %
–
[720] SCALE
–
0.00 %
–
[721] OFFSET
–
0..+10 V
–
[719] TYPE
–
FALSE
–
[718] BREAK ENABLE
–
0.00 %
–
[723] BREAK VALUE
–
Analog Output 1
0.00 %
–
[ 45] VALUE
–
100.00 %
–
[ 46] SCALE
–
0.00 %
–
[ 47] OFFSET
–
TRUE
–
[ 48] ABSOLUTE
–
0..+10 V
–
[ 49] TYPE
–
Analog Output 2
0.00 %
–
[731] VALUE
–
100.00 %
–
[732] SCALE
–
0.00 %
–
[733] OFFSET
–
FALSE
–
[734] ABSOLUTE
–
0..+10 V
–
[735] TYPE
–
Analog Output 3
0.00 %
–
[800] VALUE
–
100.00 %
–
[801] SCALE
–
0.00 %
–
[802] OFFSET
–
FALSE
–
[803] ABSOLUTE
–
0..+10 V
–
[804] TYPE
–
Digital Input 1
VALUE [ 31]
–
FALSE
FALSE – [ 30] INVERT
–
Digital Input 3
VALUE [ 37]
–
FALSE
FALSE – [ 36] INVERT
–
Digital Input 2
VALUE
[ 34]
–
FALSE
FALSE – [ 33] INVERT
–
Digital Input 4
VALUE
[ 40]
–
FALSE
FALSE – [ 39] INVERT
–
Digital Input 5
VALUE [ 43]
–
FALSE
FALSE – [ 42] INVERT
–
Digital Input 6
VALUE [726]
–
FALSE
FALSE – [725] INVERT
–
Digital Input 7
VALUE [728]
–
FALSE
FALSE – [727] INVERT
–
Digital Output 1
FALSE – [ 52] VALUE
–
FALSE
–
[ 51] INVERT
–
Digital Output 2
FALSE – [ 55] VALUE
–
FALSE
–
[ 54] INVERT
–
Digital Output 3
FALSE – [737] VALUE
–
FALSE
–
[736] INVERT
–
Inputs and Outputs
System Option
FAULT [1293]
–
NONE
ACTUAL TYPE [1294]
–
NONE
VERSION [1295]
–
0000
NONE
[1292] REQUIRED TYPE
–
Digital Input 11
VALUE
[1273]
–
FALSE
FALSE – [1272]
INVERT
–
Digital Input 13
VALUE
[1277]
–
FALSE
FALSE – [1276]
INVERT
–
Digital Input 15
VALUE
[1281]
–
FALSE
FALSE – [1280]
INVERT
–
Digital Input 12
VALUE
[1285]
–
FALSE
FALSE – [1284]
INVERT
–
Digital Input 14
VALUE [1289]
–
FALSE
FALSE – [1288]
INVERT
–
Digital Output 11
FALSE – [1283]
VALUE
–
FALSE
–
[1282]
INVERT
–
Digital Output 13
FALSE – [1287]
VALUE
–
FALSE
–
[1286]
INVERT
–
Digital Output 15
FALSE – [1291]
VALUE
–
FALSE
–
[1290]
INVERT
–
Digital Output 12
FALSE – [1285]
VALUE
–
FALSE
–
[1284]
INVERT
–
Digital Output 14
FALSE – [1289]
VALUE
–
FALSE
–
[1288]
INVERT
–
Macro Control Blocks
Some of these blocks may already be in use by the macros
Содержание 690+ series
Страница 8: ...605 Frequency Inverter HA389591 Issue 1 Contents Contents Page Cont 8 ...
Страница 222: ...Application Macros 5 12 690 Series Frequency Inverter ...
Страница 230: ...Application Macros 5 20 690 Series Frequency Inverter ...
Страница 242: ......