Assembly

1) Install hoses to inlet and outlet
filters by threading the hose end
with the straight thread “o”-ring seal
fitting into the filter flange.

2) Connect the PVC tube wands to
the swivel fitting on the hose end.

Whenever servicing the PVC tube
wand

do not overtorque the metal

fittings going into the PVC coupling.
Overtorque will result in cracking
the coupling. Generally, 1/4 turn
beyond handtight is sufficient.

Operating Instructions

1) Insert the inlet wand assembly
into the supply fluid receptacle
(drum/reservoir). The “RF". filter is
the inlet filter.

2) Insert the outlet wand assembly
into the clean fluid receptacle
(drum/reservoir). The “CF” fIlter
is the outlet filter.

Caution:
Do not kink the hose assemblies,
this may result in excessive
vacuum or pressure at the pump.

3) Verify that the ON/OFF switch is
OFF and plug the cord into a 115V
10A grounded outlet (3 wire).

4) Turn switch to ON position and
check outlet wand for oil flow.
Allow 30 to 60 seconds for filters to
fill with oil. If repeated attempts to
obtain oil flow fail, check pump inlet
fittings for tightness, remove inlet
filter access cover and verify the
cover sealing “o”-ring is in place.
For very viscous fluids it may be
necessary to pour 1 or 2 quarts of
fluid into the “RF” inlet filter housing
to prime pump initially.

5) The condition of the filter ele-
ment should be monitored by
observing the cleanliness indicator
on the discharge filter. When the
Indicator is in the CHANGE posi-
tion, both inlet and outlet filter
elements MUST be replaced to
prevent fluid from going into
bypass in the filters.

6) The inlet filter Is provided with
a 3PSI bypass spring, and
prevents the pump from cavitat-
ing If the element is not
changed. The outlet filter is
provided with a 25PSl bypass
spring to prevent excessive
pressure which may be harmful
to personnel or to the filter cart.

Warning:
The filter bypass spring acts as a
relief valve for the pump. Do not
restrict the discharge hose with
a shut-off valve which will defeat
the function of the bypass valve,
causing excessive pressure,
which may be harmful to person-
nel or to   the filter cart.

7) The cleanliness indicator
works on differential pressure
and will indicate the condition of
the element (CLEAN, CHANGE,
or BYPASS).

NOTE:
The filter cart must be in
operation for the indicator
to read properly.

Maintenance
Instructions

1) Turn switch to OFF position and
unplug cord from electrical outlet.
2) Remove tube wands from oil to
prevent siphoning.
3) Loosen hex head screws on
filter cover. Turn cover to clear
screws, remove cover.
4) Pull flow diverter assembly from
the filter head. Filter element will
follow the diverter.

a) Replace the cellulose,
synthetic or Microglass II
elements. Verify replacement.
b) Wire mesh elements can be
cleaned. Ultrasonic cleaners
provide best results.

5) Install element on flow diverter
and reinstall in filter housing. Make
sure diverter “o"-rings seat
properly into  the head.
6) Check to be sure that the notch
on the flow diverter lines up with
the notch in the head.
7) Inspect the cover “o"-ring and
replace if necessary.
8) Replace cover and tighten hex
head screws until they are snug.
Do not over-torque these screws.
Do not interchange the inlet filter
cover with the outlet filter cover.
(The inlet filter has a “RF” prefix,
the outlet filter has a "CF" prefix).

  Problem

Cause

Solution

  Does not start.

ON/OFF switch.

Turn switch ON, replace switch if defective.

No electrical power.

Plug in cart.

Defective motor.

Replace.

Filter housing not filled with oil.

Allow pump to run 30 to 60 seconds.

Suction leak.

Check tightness of inlet fittings.
Check "o"-ring in inlet filter cover for nicks.
Kink or restriction in inlet hose.
Add 1 or 2 quarts of oil to inlet filter.

Defective pump.

Replace pump.

Element dirty.

Replace or clean elements (both filters).

Oil extremely cold or viscous.

Change element to coarser micron rating.

  or  BYPASS.

No outlet element.

Install element.

40 micron element installed

Check cart model number to verify correct

in outlet filler.

 element. The inlet filter has a rating "RF"
 prefix; the ouflet filter has a "CF" preflx.

Troubleshooting

No oil flow or
erratic pump noise.

Indicator does not
seem to move.

Indicator reads
CHANGE

Содержание 5MF

Страница 1: ...Portable Filter Carts Models 5MF and 10MF Global Filtration Technology 149 ...

Страница 2: ...servoirs or to clean up existing systems Fluid should always be filtered before being put into use New fluid is not necessarily clean fluid Most new fluids right out of the drum are unfit for use due to high initial contamination levels Contamina tion both particulate and water may be added to a new fluid during processing mixing handling and storage Water is removed by installing Par Gel elements...

Страница 3: ...ulate and water removal Visual Indicator Tells you when to change elements Motor Industrial brand name Heavy Duty Frame Rugged and built to last Drip Pan Helps keep the work area safe and clean Electrical Cord not shown 6ft with on off switch Optional 20 ft cord with reel Gear Pump Industrial quality Quiet operation Dependable long life Hose Wand Assembly Ready to use no additional hardware needed...

Страница 4: ...ential type 3 band clean change bypass Filter Bypass Valve Settings Inlet 3 psid 2 bar Outlet 25 psid 1 7 bar OperatingTemperatures Buna N Nitrile 40 F to 150 F 40 C to 66 C F3 high temp option 15 F to 200 F 26 C to 93 C Electrical Service Required 115 volts 10 amps single phase 60 Hz Electrical Motor l0MF hp 3450 rpm O D P 5MF hp 1725 rpm O D P Thermal overload protection Construction Cart Frame ...

Страница 5: ...C element 3 System ingression rate equal to 1 X 106 particles greater than 10 micrometers entering the system per minute Filter Cart Element Performance Time Averaged Media Filter Beta x y z 2 20 75 Capacity Code Media Where x y z is Grams 74W Woven Wire 0 00291 40W Woven Wire 0 00161 40SA Synthetic 40 Micron Nominal2 20C Cellulose 20 Micron Nominal2 10C Cellulose 6 18 22 Micron 15 03C Cellulose 2...

Страница 6: ...ct the discharge hose with a shut off valve which will defeat the function of the bypass valve causing excessive pressure which may be harmful to person nel or to the filter cart 7 The cleanliness indicator works on differential pressure and will indicate the condition of the element CLEAN CHANGE or BYPASS NOTE The filter cart must be in operation for the indicator to read properly Maintenance Ins...

Страница 7: ...ssembly 15 928727 TubeFitting 1 16 928663 Hose Assy Buna N 2 16 928621 HoseAssy Fluorocarbon 17 928784 Tube Wand Assy Buna N 2 17 928620 TubeWandAssy Fluorocarbon 18 932187 Name Plate 1 19 RF2 1 PP3 YN F9 1 Inlet Filter Buna N 1 19 F3 RF2 1 PP3 YN F9 1 InletFilter Fluorocarbon 20 CF2 1 MP25 F9 YN 1 OutletFilter Buna N 1 20 F3 CF2 1 MP25 F9 YN 1 OutletFilter Fluorocarbon Buna Seals Fluorocarbon Med...

Страница 8: ...oglass III 05Q Microglass III 02Q Microglass III WR PAR GEL Water Removal Applied to the filter by Parker Hydraulic Filter Division Use the full model code including the design number when ordering replacement parts BOX 2 MODEL Symbol Description 10MF 10 GPM 500 SUS MAX 5MF 5 GPM 3000 SUS MAX BOX 3 INLET FILTER Symbol Description BOX 5 OPTIONS Symbol Description 1 None 3 Magnets in inlet filter 6 ...

Страница 9: ...Global Filtration Technology Guardian Portable Filtration System 157 ...

Страница 10: ... Most new fluids right out of the drum are unfit for use due to high initial concentrations of contaminants Contamination may be added to a new fluid during processing mixing handling and storage The Guardian also circulates and polishes fluid in your existing systems to reduce the contamination to an acceptable level There are literally hundreds of applications that the Guardian is suited for wit...

Страница 11: ...etween changes microglass to 74 micron cleanable wire and water removal Clear wire reinforced No additional Ready to use and easy 5 hose assemblies hardware required to maneuver with wand attachments Optional quick Fast easy setup and Eliminates messy disconnect hose tear down drips connections Heavy duty HP UL recognized and Safe reliable 115 VAC 230 VAC CSA listed with performance field 24 VDC o...

Страница 12: ...s 500 hours Weight approximately 23 lbs 5 oz Materials Housing cast aluminum Cover die cast aluminum Handle and Indicator nylon Wands and Hose PVC Fittings brass Seals fluorocarbon carboxylated nitrile Guardian Schematic 10 24 Terminal Studs 2 places 24 VDC On off switch 50 8 2 00 152 4 6 00 Alternate customer exchangeable 14 NPT inlet and outlet locations Plugged Inlet Outlet 195 7 68 Motor is UL...

Страница 13: ...ity SUS Efficiency Beta at x Rating Particle Size Guardian Flow vs Viscosity Performance Multipass test run at 4 gpm to 35 psid 1 Reference ratings only Not multipass tested due to coarseness Not applicable Elements Used Media New Oil ISO ISO Achieved Element Life per 250 gallons 10C 22 20 16 21 19 15 120 gallons 2 08 20Q 22 20 16 21 19 15 486 gallons 51 10Q 22 20 16 19 16 14 407 gallons 61 05Q 22...

Страница 14: ...cause the motor to overheat stop operation and cycle intermittently Worn motor brushes Replace motor brushes Defective motor Replace motor Hot motor Pumping under heavy load It is normal under a heavy pumping load for the motor to reach 160 F Defective motor Replace motor if shell temperature reaches greater than 170 F No flow or erratic Filter housing not filled with oil Allow Guardian to run a f...

Страница 15: ... Ring V72041 18 Handle 931897 31 Outlet Hose Assembly 931937 6 Polypak Seal 931921 19 Cover 931892 32 Wand Crevice Assembly 931965 7 Shadow Plate 931899 20 Cover O Ring V72237 33 Wand Adapter Assembly 931966 8 Woodruff Key 1 8 x 3 8 931877 21 Element 34 Washer 2 926106 9 SHCS 4 20 x 902679 22 Relief Valve 928981 35 Quick Disconnect Kit 932097 10 Roll Pin 1 8 x 903630 23 Indicator Kit 927422 Not Sh...

Страница 16: ...None 6 Quick disconnect hose connections BOX 5 DESIGN NUMBER Symbol Description Applied to the Guardian by Parker Hydraulic Filter Division Use the full model code including the design number when ordering replacement parts 74W Wire Mesh 40W Wire Mesh 25W Wire Mesh 20C Cellulose 10C Cellulose 20Q Microglass III 10Q Microglass III 05Q Microglass III 02Q Microglass III WR Water Removal BOX 3 MEDIA S...

Страница 17: ...Portable Purification Systems Models PVS 185 600 1200 1800 2700 165 Global Filtration Technology ...

Страница 18: ... as Corrosion by etching metal Fluid breakdown reduction of lubricating properties additive precipitation and oil oxidation Reduced dielectric strength Abrasive wear in hydraulic components Free water occurs when oil becomes saturated and cannot hold any more water This water is usually seen as cloudy oil or puddles of water at the bottom of an oil reservoir Water which is absorbed into the oil is...

Страница 19: ...l Available with EPR seals and stainless steel Solid state heater contacter Benefits Eliminate potential hazard of exhausting to atmosphere Reduced maintenance costs Fits through doorways and down narrow aisles Increased use Employee safety Easily transported Unattended operation Increases oil life Reduced labor costs Increased running time Flexibility less maintenance Prevents incorrect rotation ...

Страница 20: ... Have limited water removal capability due to absorbing material only removes air ingressed particles expensive compared to the volume of water removed Coalescer units Removes free water only has difficulty breaking stable emulsions does not work well in viscous fluids 100 sus much larger in size compared to PVS When utilizing 2Q media Potential Contaminant Solid particulate Water Air Gases PVS Pe...

Страница 21: ... pressure max 60 psi 4 1 bar Ports 3 4 JIC male inlet 3 4 JIC male outlet FLA full load amps 15 30 amps Depending on voltage used PVS 185 REPLACEMENT ELEMENTS PARTICULATE 2Q 2 micron 932665Q 5Q 5 micron 932666Q 10Q 10 micron 932667Q 20Q 20 micron 929927Q DISPERSAL Disposable 933180 Coalescing Packed tower 933553 Cleanable CORELESS 02QE 933734Q 05QE 933612Q 10QE 933735Q 20QE 933736Q PVS 185 Flow Di...

Страница 22: ...Ring Vacuum Pump Flow Direction REPLACEMENT ELEMENTS PARTICULATE 2Q 2 micron 932665Q 5Q 5 micron 932666Q 10Q 10 micron 932667Q 20Q 20 micron 929927Q DISPERSAL Disposable 933180 Coalescing Packed tower 933553 Cleanable CORELESS 02QE 933734Q 05QE 933612Q 10QE 933735Q 20QE 933736Q S P E C I F I C A T I O N S Flow rate 10 gpm 37 9 lpm Height 60 1524 mm Width 25 635 mm Length 36 914 mm Weight 750 lbs 3...

Страница 23: ... full load amps 30 48 amps Depending on options voltages Air Cooled Condenser Option Condensate Drain Inlet Flow Oil Discharge Pump Vacuum Gauge Air Breather Low Watt Density Heater 11 WPSI WPSI Watts p Dry Sealed Vacuum Pump Oil Lubricator High Level Condensate T 8 3 Gallon Tank High Level Switch Low Oil Flow Switch T Cooling Water Out Water Cooled Condenser Option Cooling Water In 1 5 GPM 5 7 LP...

Страница 24: ...933734Q 05QE 933612Q 10QE 933735Q 20QE 933736Q 172 S P E C I F I C A T I O N S Flow rate 30 gpm 113 6 lpm Height 65 1651 mm Width 40 1016 mm Length 72 1829 mm Weight 1700 lbs 772 kg Seal material Fluorocarbon EPR opt Condensate tank 8 3 gal 31 4 ltrs Dispersal elements 8 Minimum operating capacity 18 gal 68 1 ltrs Vacuum max 25 in hg Viscosity max 500 sus 108 cSt Disposable 2150 sus 460 cSt Packed...

Страница 25: ...02QE 933734Q 05QE 933612Q 10QE 933735Q 20QE 933736Q S P E C I F I C A T I O N S Flow rate 45 gpm 170 3 lpm Height 70 1778 mm Width 60 1524 mm Length 72 1829 mm Weight 1800 lbs 817 kg Seal material Fluorocarbon EPR opt Condensate tank 8 3 gal 31 4 ltrs Dispersal elements 8 Minimum operating capacity 18 gal 68 1 ltrs Vacuum max 25 in hg Viscosity max 500 sus 108 cSt Disposable 2150 sus 460 cSt Packe...

Страница 26: ...SUPPLY Model Symbol Description 220 220VAC 1P 60HZ 230 230VAC 3P 60HZ 185 380 380VAC 3P 50HZ 460 460VAC 3P 60HZ 550 575VAC 3P 60HZ 230 230VAC 3P 60HZ 380 380VAC 3P 50HZ 600 460 460VAC 3P 60HZ 550 550VAC 3P 60HZ 380 380VAC 3P 50HZ 1200 460 460VAC 3P 60HZ 550 550VAC 3P 60HZ 380 380VAC 3P 50HZ 1800 460 460VAC 3P 60HZ 550 550VAC 3P 60HZ 380 380VAC 3P 50HZ 2700 460 460VAC 3P 60HZ 550 550VAC 3P 60HZ BOX...

Отзывы: