![Parker 514C Скачать руководство пользователя страница 12](http://html2.mh-extra.com/html/parker/514c/514c_product-manual_3744368012.webp)
1-6
Product Overview
514C Product Manual
EMC TECHNICAL RATINGS
Immunity
Port
Phenomenon
Test Standard
Level
Criterion
Generic
Standard
Enclosure
Port
ESD
RF Field
BS EN 61000-4-2
(1995)
8kV AD
10V/m,1kHz, AM
Self Recovery
No Change
EN50082-1
(1992),
RF Field Pulse
Modulation
ENV 50140 ENV
50204
10 V/m P.M.
Self Recovery
and
EN50082-2
Power
Ports
Fast Transient
Burst
BS EN 61000-4-4
(1995)
2kV
Self Recovery
(1995)
Bulk Current
Injection
ENV 50141
10V, 1kHz, AM No Change
Surge Test
BS EN 61000-4-5
(1995)
2kV Common
Mode
2kV Differential
Mode
Self Recovery
Signal &
Control
Fast Transient
Burst
BS EN 61000-4-4
(1995)
2kV
Self Recovery
Bulk Current
Injection
ENV 50141
10V, 1kHz, AM No Change
Power
Interfaces
Fast Transient
Burst
BS EN 61000-4-4
(1995)
2kV
Self Recovery
Bulk Current
Injection
ENV 50141
10V, 1kHz, AM No Change
Emissions
Port
Phenomenon
Test Standard
Level
Generic Standard
Enclosure Port
Radiated
EN55011
Class B # EN50081-1 (1992),
Power Port
Conducted
EN55011
Class B *
EN50081-2 (1994)
Notes: These levels of performance are achieved when installed as specified with the
recommended Supply Filter.
*
Achieved with up to 50m of motor cable.
#
Achieved with unscreened signal
and control cables.
PRODUCT CODE
Block
Product
Code
Feature
1
Basic Product
514C
2
Current Rating
04
4 amp
08
8 amp
16
16 amp
32
32 amp
3
Livery
00
Standard
01 to 99
Customer
4
Cover
00
IP00 Open Frame
5
Special Options
00
Standard
01-99
Documented Special Options