ELECTRICAL

 

FEATURES

 

 

The DA1500 unit is built to operate from either 230VAC or 460VAC (not interchangeably), 
50/60 Hz., Single phase current. Line current at rated output is approximately 45 amperes at 
230 volts and 23 amperes at 460 volts. Check  "Data Nameplate" on the unit for correct 
operating voltage. 
 
The DA1500 is sold without a power cord plug. Only locally approved plugs with the proper 
rating should be used and installed by certified personnel. 
 
The DA1500 is wired at the factory for either 230VAC or 460VAC operating voltage. Change 
over from one voltage to another can not be done in the field. Unit must be returned to the 
factory for modification.  
 
An automatic thermal reset circuitbreaker is provided to prevent overheating and damage to 
electrical components. 
 
The current control potentiometer in conjunction with internal electrical circuit, provide infinitely 
variable magnetizing and demagnetizing current control. 
 
The power transformer operating in conjunction with an SCR module, transforms the high 
voltage line input to low voltage, high amperage AC or Half-Wave DC output.  While these 
components are fan cooled, they are designed for intermittent service at 1500 amperes output. 
To avoid overheating and possible damage, a minimum duty cycle of 50% must be adhered to. 
 

CAUTION

: Attaching less than 30' of 4/O cable (two 15' cables) may cause excessive line 

current draw and possible overheating of parts. 
 

CONNECTION

 

 
1. With current control in the "Off" position, connect the line cord to the properly fused and 
grounded disconnect switch of proper rating. Consult "Data Nameplate" on the back of the unit 
for correct operating voltage. 
 
2. Turn the current control so that the unit powers "On".  A red pilot light will glow indicating 
that there is power to the unit and that it is "On". 
 
3. Plug in and twist clockwise two 15' 4/O magnetizing cables into the output connectors at the 
front of the unit. 

Note:

 One cable must be connected to the "Common" connector. The other 

cable must be connected to either the A.C. or HWDC cable connector. Connect the two 
eitherend connectors or two lug connectors at the opposite end of the cables to form a "loop".  
Plug in the control cable and activate to check operation for both AC and DC output.  
 
For maximum output on either AC or half-wave DC, it is necessary to reduce the inductive loop 
of the external cables as much as possible\; that is, the spacing  
between the external  4/O cables must be kept at a minimum. If possible, the first ten feet of 
cable may be bound of taped together for optimum current output. 

NOTE

: When cables are used  as a coil with AC current, ammeter readings will be lower due 

to coil/part  inductance.     

 

 

 

 

      

 

Содержание DA-1500

Страница 1: ...on It features infinitely variable magnetizing and demagnetizing current THE FOLLOWING SHOULD BE READ AND FULLY UNDERSTOOD SAFETY PRECAUTIONS PAGE 2 GENERAL DESCRIPTION PAGE 2 ELECTRICAL FEATURES PAGE 3 CONNECTION PAGE 3 CONTROLS ELECTRICAL PAGE 4 OPERATION PAGE 5 SERVICE DATA WARRANTY PAGE 6 SCHEMATIC DIAGRAM PAGE 7 8 Parker Research Corporation assumes no liability from any claims arising from t...

Страница 2: ... devices should not operate this machine and must stay a safe distance away from this machine and cable output area Contact the manufacturer of your Pacemaker for additional precautions and warnings GENERAL DESCRIPTION The DA1500 is a extremely rugged and compact Magnetic Inspection unit All operating controls and output terminals are located on the front panel Two carrying handles are provided On...

Страница 3: ...ible damage a minimum duty cycle of 50 must be adhered to CAUTION Attaching less than 30 of 4 O cable two 15 cables may cause excessive line current draw and possible overheating of parts CONNECTION 1 With current control in the Off position connect the line cord to the properly fused and grounded disconnect switch of proper rating Consult Data Nameplate on the back of the unit for correct operati...

Страница 4: ... Wave connectors A C current is obtained by connecting to the Common and AC connectors Always insert and then twist cable connectors clockwise to lock in position CONTROL CABLE RECEPTACLE This receptacle is located below the current control Twist and lock the control cable in the receptacle PROD CONTROL SWITCH Various optional prod assemblies have a control switch built into the handle It is conne...

Страница 5: ...le into Control Cable Receptacle 3 Turn current control to position that gives desired current level 4 Make prod contacts with clean surface of part Place prod tips approximately six inches apart on either side of the line of suspected defect Press prod handle switch to initiate current flow Use very firm contact pressure to minimize chances of arcing and burning Ammeter will indicate magnetizing ...

Страница 6: ...f the DA1500 at no charge less incoming freight charges for a period of one 1 year from the date of purchase Warranty will not apply to units that have been altered or to those units that have been used improperly In the event of malfunction return the unit prepaid to the factory Repair or replacement of the defective unit will be made at the discretion of Parker Research Corporation The repaired ...