SAFETY PRECAUTIONS 

  

 

The following safety precautions must be fully understood and applied during the installation, 
operation and maintenance of this equipment. These safety precautions appear throughout the 
text and are covered here for emphasis. 
 

A

. "

DANGER

" Ground this equipment before operating. Failure to ground this unit properly 

may result in electrical shock hazard. 
 

B

. "

CAUTION

" Use safety glasses when operating this equipment. 

 

C.

 "

DANGER

" Line current must be disconnected before equipment panels are removed for 

any reason. Only qualified electrical personnel should attempt service. 
 

D

. "

CAUTION

" When performing prod inspection with this unit, use very firm contact pressure 

to minimize chances of arcing. 
 

E

. "

WARNING

" This equipment produces a strong electromagnetic field which can be harmful 

to people with implanted Cardiac Pacemakers.  Personnel with such devices should not 
operate this machine and must stay a safe distance away from this machine and cable output 
area.  Contact the manufacturer of your Pacemaker for additional precautions and warnings. 
 
 

 

 

 

 

GENERAL

 

DESCRIPTION

 

 

The DA1500 is a extremely rugged and compact Magnetic Inspection unit. 
 
All operating controls and output terminals are located on the front panel. Two carrying 
handles are provided. One on the rear of the unit; the other is a swivel handle located at the 
front of the unit. This handle may also be positioned to raise the front of the unit for ease of 
meter reading and operation. 
 
Current output is approximately 1500 amperes low voltage A.C. and approximately 1500 
amperes half-wave D.C. The current output is based on the use of 30 feet (two 15') cables as a 
load. Current levels will vary dependent on cable length. 
 
Optional magnetizing cables can be equipped with prods for circular magnetization. The cables 
can also be wrapped around parts to form a "coil" for longitudinal magnetization. 
Demagnetization is accomplished in a similar manner. 
 
 
 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 
 

Содержание DA-1500

Страница 1: ...on It features infinitely variable magnetizing and demagnetizing current THE FOLLOWING SHOULD BE READ AND FULLY UNDERSTOOD SAFETY PRECAUTIONS PAGE 2 GENERAL DESCRIPTION PAGE 2 ELECTRICAL FEATURES PAGE 3 CONNECTION PAGE 3 CONTROLS ELECTRICAL PAGE 4 OPERATION PAGE 5 SERVICE DATA WARRANTY PAGE 6 SCHEMATIC DIAGRAM PAGE 7 8 Parker Research Corporation assumes no liability from any claims arising from t...

Страница 2: ... devices should not operate this machine and must stay a safe distance away from this machine and cable output area Contact the manufacturer of your Pacemaker for additional precautions and warnings GENERAL DESCRIPTION The DA1500 is a extremely rugged and compact Magnetic Inspection unit All operating controls and output terminals are located on the front panel Two carrying handles are provided On...

Страница 3: ...ible damage a minimum duty cycle of 50 must be adhered to CAUTION Attaching less than 30 of 4 O cable two 15 cables may cause excessive line current draw and possible overheating of parts CONNECTION 1 With current control in the Off position connect the line cord to the properly fused and grounded disconnect switch of proper rating Consult Data Nameplate on the back of the unit for correct operati...

Страница 4: ... Wave connectors A C current is obtained by connecting to the Common and AC connectors Always insert and then twist cable connectors clockwise to lock in position CONTROL CABLE RECEPTACLE This receptacle is located below the current control Twist and lock the control cable in the receptacle PROD CONTROL SWITCH Various optional prod assemblies have a control switch built into the handle It is conne...

Страница 5: ...le into Control Cable Receptacle 3 Turn current control to position that gives desired current level 4 Make prod contacts with clean surface of part Place prod tips approximately six inches apart on either side of the line of suspected defect Press prod handle switch to initiate current flow Use very firm contact pressure to minimize chances of arcing and burning Ammeter will indicate magnetizing ...

Страница 6: ...f the DA1500 at no charge less incoming freight charges for a period of one 1 year from the date of purchase Warranty will not apply to units that have been altered or to those units that have been used improperly In the event of malfunction return the unit prepaid to the factory Repair or replacement of the defective unit will be made at the discretion of Parker Research Corporation The repaired ...

Страница 7: ...7 ...

Страница 8: ...8 ...

Отзывы: