SAFETY PRECAUTIONS
The following safety precautions must be fully understood and applied during the installation,
operation and maintenance of this equipment. These safety precautions appear throughout the
text and are covered here for emphasis.
A
. "
DANGER
" Ground this equipment before operating. Failure to ground this unit properly
may result in electrical shock hazard.
B
. "
CAUTION
" Use safety glasses when operating this equipment.
C.
"
DANGER
" Line current must be disconnected before equipment panels are removed for
any reason. Only qualified electrical personnel should attempt service.
D
. "
CAUTION
" When performing prod inspection with this unit, use very firm contact pressure
to minimize chances of arcing.
E
. "
WARNING
" This equipment produces a strong electromagnetic field which can be harmful
to people with implanted Cardiac Pacemakers. Personnel with such devices should not
operate this machine and must stay a safe distance away from this machine and cable output
area. Contact the manufacturer of your Pacemaker for additional precautions and warnings.
GENERAL
DESCRIPTION
The DA1500 is a extremely rugged and compact Magnetic Inspection unit.
All operating controls and output terminals are located on the front panel. Two carrying
handles are provided. One on the rear of the unit; the other is a swivel handle located at the
front of the unit. This handle may also be positioned to raise the front of the unit for ease of
meter reading and operation.
Current output is approximately 1500 amperes low voltage A.C. and approximately 1500
amperes half-wave D.C. The current output is based on the use of 30 feet (two 15') cables as a
load. Current levels will vary dependent on cable length.
Optional magnetizing cables can be equipped with prods for circular magnetization. The cables
can also be wrapped around parts to form a "coil" for longitudinal magnetization.
Demagnetization is accomplished in a similar manner.