15 - Installing the protective top and the antenna with or without zone indicator
StradaPAL – Installation manual
37/43
15.
Installing the protective top and the antenna with or without
zone indicator
Check that the unused holes present on the top of the housing are protected
with the capping assemblies (1 screw, 2 washers and 1 nut) that keep them
sealed (2 holes unused with Ethernet communication, 1 hole otherwise).
Tools required (excluding work before replacement):
-
13-mm open-ended spanner.
Installation:
Route the cable of the communication antenna through the hole provided in
the zone indicator (if present).
Install the protective top on the zone indicator (if present) by inserting the
four threaded rods (with a cone of sealing filler) in the four holes provided.
Fasten the four collar nuts from below the zone indicator (if present) using a
13-mm key.
Route the cable of the communication antenna through the hole provided on
the top of the housing.
Fit the top/zone indicator assembly (if present) on the top of the housing by
inserting the four threaded rods (with a cone of sealing filler) in the four
holes provided.
Fasten the four collar nuts from the maintenance compartment using a 13-
mm key.
Installing with indicator
Protective
top
Communication
antenna cable
Zone indicator
(optional)
Housing