MOUNTING METHODS
There are two different Mounting Methods.
First cut out the Mounting Template along Line “A” before proceeding.
METHOD #1
This method is for easy mounting to
painted
surfaces with smooth to medium
textures such as painted wood, drywall with or without texture, concrete or
concrete blocks and bricks.
This method is not recommended for heavy textured
stucco or unpainted surfaces.
1.
Clean mounting surface with isopropyl alcohol or a mild cleaning solvent
before mounting the Infrared Head Units.
2.
With the Mounting Template cut out, hold the Mounting Template on the
mounting wall and line up line “B” to the distance measurement and line up
line “C” to the height measurement. When both lines are lined up, with a
pencil, trace the cut out Mounting Template on the wall surface. Repeat
this procedure on the opposite mounting wall.
3.
Remove the paper backing from the mounting tape on the back of the
Infrared Head Unit. Carefully place the Infrared Head Unit to the template
outline on the mounting wall. Once in place, firmly press the Infrared Head
Unit to the mounting wall to seat the Mounting tape. Repeat on the other
mounting wall with the remaining Infrared Head Unit.
Please be advised that when removing installed Infrared Head Units using this
mounting method, it may result in leaving a glue residue on the wall or possibly
removing paint from the wall.