PARK AUDIO RX Series Скачать руководство пользователя страница 7

FUNCTIONAL FEATURES

Output Overload and Short-Circuit Protection 

Individual per each channel. Protects the output stage of the amplifier units against 

short-circuiting, as well as limits the output current, when a maximum-level sine signal is 
applied continuously to 2-Ohms loudspeaker.

In case short-time overload (e.g. overload, caused by a sudden drop of complex load 

impedance), the fast output stage protection system  limits the output current to 60 A. 

In case of long-term overload (>0.5 sec), the slow protection system limits the output 

current to 40 A. 

In case of a short circuit, the protection system momentarily blocks the output of the 

amplifier. The processor periodically tries to turn on the amplifier. If the short-circuit persists 
for a long time, test attempts are made less often.

The protective system does not switch the amplifier off, so it resumes its unattended 

operation after the short-circuiting conditions are gone.

Built-in to each channel microprocessor ensures safe operation.

DC Output Protection

Independent for each pair of channel. Prevents DC damage to loudspeakers.  

The amplifier’s schematics precludes transit of any clicks or noise during the power-

on/off transition process. 

Protection of loudspeakers against DC damage is ensured for each pair of  channel by 

individual power supply units which are disabled in the event of output DC voltage or any 
powerful LF fluctuations.  In case the protection system becomes active on all channels and 
both power supply units become disabled, all indicators go off. 

The amplifier can be restarted with the POWER toggle switch, by way of turning the 

amplifier off and turning it on, about 2 minutes later again.

Thermal Protection

Individual  for  each  channel.  Protects  the  amplifier’s  output  stage  against 

overheating. 

In case the temperature of the output stage transistors rises to 80°С, the CLIP LED of 

the corresponding channel lights up. At the same time, the thermal protection system will 
gradually  reduce  the  signal  level  as  the  temperature  increases.  When  the  output  stage 
reaches 85°C, the thermal protection system will block the input and output stage of the 
corresponding  amplifier  channel.    After  the  temperature  drops  to  70°С  ,  the  amplifier 
automatically resumes operation.

Soft Start

Reduces the power-on inrush current.

The  soft  start  system  is  provided  to  reduce  inrush  current  to  the  amplifier  and  to 

minimize  the  noise  contributed  by  the  amplifier  to  the  power  mains  during  the  poweron 
process.

Soft Signal Start

Ensures smooth power-on sound signal rise.

During  the  power-on  process,  this  feature  ensures  smooth  gain  from  zero  to  the 

maximum  level  to  provide  for  a  smooth  rise  of  the  sound  level  emitted  from  the 
loudspeakers.

5

Содержание RX Series

Страница 1: ...series 9d FOUR CHANNEL PROFESSIONAL SWITCHING POWER AMPLIFIER Owner s Manual...

Страница 2: ...ACCESSORIES 1 Power Cord 1 pc 2 Dust filter 2 pcs 3 Owner s Manual 1 pc 4 Warranty 1 pc...

Страница 3: ...AUTION The amplifier can yield dangerous output voltage Do not touch the non insulated cable parts connected to the unit in operation CAUTION The high sound pressure caused by the high output signal a...

Страница 4: ...ck fan vents Do not place the unit near heating radiators furnaces or other heat emitting devices Do not connect this unit to an ungrounded power supply line Protect the power cord against damage Disc...

Страница 5: ...lanced inputs provides for an essential reduction of the environment induced hum and noise interference with long input connecting cables For DSP processing the analog signal is converted to digital u...

Страница 6: ...the tools for group control of many amplifiers simultaneously The amplifier can be supplied with pre formed library of passive speakers Software is designed for group control of a large number of ampl...

Страница 7: ...sured for each pair of channel by individual power supply units which are disabled in the event of output DC voltage or any powerful LF fluctuations In case the protection system becomes active on all...

Страница 8: ...power supply Only the protection system stand by power supply unit remains in operation The system activates whenever the mains voltage exceeds 265V The amplifier automatically resumes operation after...

Страница 9: ...AMPLIFIER BLOCK DIAGRAM 1 1 2 2 1 Ch1 AES1 2 INPUT Power amplifier Ch 1 1 2 2 THRU THRU Ch1 Ch2 OUTPUTS TO SPEAKERS Ch2 Ch 2 Ch 3 Ch 4 THRU THRU Ch3 Ch4 Ch4 Ch2 AES3 4 Ch 3 Ch 4 INPUT INPUT INPUT DSP...

Страница 10: ...ers activation LEDs CLIP overload LEDs for channels 1 2 3 and 4 Indicating overload and distortion occurence 2 x 20 characters LCD display DSPCONTROL encoder knob for the menu navigation and parameter...

Страница 11: ...assignment are marked on the amplifier rear panel MAINS IN mains cable connector THRU line outputs Used for sending the input signal to another amplifiers In analog signal mode THRU connectors are pa...

Страница 12: ...reased damping factor and possible fire hazard Since the power applied to the loudspeaker is of primary concern in system design we have included the table below to allow you determine the appropriate...

Страница 13: ...of both channels via a single cable use SpeakON NL4FC CAUTION Never attempt to jumper or otherwise link up any pins of output connectors 2 1 3 2 1 3 1 1 1 2 1 2 1 2 1 2 XLR Wiring male XLR Wiring fema...

Страница 14: ...e amplifier to a household mains If connected to weak power supply mains the output power of the amplifier may be reduced producing the so called feeble bass effect or the power supply line may be dam...

Страница 15: ...tely STORE PRESET current setting store as user preset into Preset Library in one of the memory cells 1 92 SETUPIP amplifier IP address setting SELECT INPUT input mode choise analog or digital AES EBU...

Страница 16: ...ed in the upper line of the LCD display Rotating the DSP CONTROL knob changes parameter with step 0 1dB The step can be changed from 0 1dB to 1dB and vice versa by short clicking DSPCONTROLknob No par...

Страница 17: ...ith your nger shown in the gure below and pull it toward The locking latch must be unlocked After that carefully remove the cover and the lter A heavily dusted lter can be washed in any synthetic dete...

Страница 18: ...35 dB Power Requirements 230 V 50 60 Hz Weight 12 kg Dimensions 482 mm W 96 mm H 442 mm D DSP Parameters SHARC DSP 96 kHz sampling rate 40 bit oating point ADC 120dB SNR 100 dB THD N 18 dBU Input Leve...

Страница 19: ...4x2200W DIMENSIONS 482 440 max 439 442 465 76 88 96 428 12 17...

Страница 20: ...PARK AUDIO II Ltd Vinnytsia Ukraine www parkaudio ua park parkaudio ua...

Отзывы: