TROUBLESHOOTING
No Sound Signal on the Amplifier’s Output
POWER LED is OFF:
– damaged power cable;
– no power;
– DC protection mode.
But for POWER LED all other LEDs are OFF:
– no input signal;
– input level attenuators are set to minimum position.
SIGNAL and CLIP LEDs are occasionally blinking:
– output cable is short-circuited;
– load impedance is too low.
THERMAL LED and one or several CLIP LEDs are ON while SIGNAL LEDs of
these same channels are OFF:
– the respective channels are in the overheating protection mode (the heat
sink temperature is over 85°С).
Reduced Output Signal Level
THERMAL LED is slightly lit:
– the unit is protected against overheating (heat sink temperature has exceeded
65°С thus activating the thermal protection system).
Sound Distortion
Only SIGNAL LED is ON:
– applied input signal is distorted before it gets to the amplifier;
– loudspeakers are damaged.
If input level attenuators are set close to their minimum position, distortion
may occur as a result of input stage overload with high input signal.
Both SIGNAL and CLIP LEDs are ON:
– overload caused by low load impedance or too high input signal level.
Hum and Interference
Make sure to have the power cord 3-wire plug properly connected to a grounded
outlet. Disconnecting the ground contact usually does not eliminate hum and
interference but may pose a risk of electric shock.
To reduce hum and noise, use balanced connections.
Interference can also be caused by lighting intensity controls (dimmers), as well
as by neon or luminescent tubes.
18
Содержание DF series
Страница 1: ...PROFESSIONAL FOUR CHANNEL CLASS D POWER AMPLIFIER DF1 404 MKII Owner s Manual DF series R...
Страница 2: ...ACCESSORIES 1 Power Cord 1pc 2 Owner s Manual 1pc 3 Warranty 1pc...
Страница 22: ...445 max 482 466 76 88 96 38 324 362 DIMENSIONS 20...
Страница 23: ...PARK AUDIO II Ltd Vinnytsia Ukraine www parkaudio ua e mail park parkaudio ua R...