Grounding Instructions
NOTE:
Do not use adapters shown in figures B & C in Canada
3
This machine must be grounded. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This machine is equipped with a cord having an
equipment-grounding conductor and grounding plug. The plug must be
inserted into an appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
WARNING
- Improper connection of the equipment-grounding conductor
can result in a risk of electric shock. Check with a qualified electrician or
service person if you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided with the machine. If it will
not fit the outlet, have a proper outlet installed by a qualified electrician.
This machine is for use on a nominal 120-volt circuit, and has a grounded
plug that looks like the plug illustrated in figure A. A temporary adapter
that looks like the adapter illustrated in figures B and C may be used to
connect this plug to a 2-pole receptacle as shown in figure B if a properly
grounded outlet is not available. The temporary adapter should be used
only until a properly grounded outlet (figure A) can be installed by a quali
-
fied electrician. The green colored rigid ear, lug, or the like extending from
the adapter must be connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter is used, it must be held
in place by a metal screw.
NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code.
EXTENSION CORDS
Use only three-wire 14/3 or larger gauge approved extension cords that
have three-prong grounding type plugs and three-pole receptacles that
accept the appliance’s plug. Replace or repair any damaged cords or plugs.
When servicing, refer to authorized person only. Use only identical re
-
placement parts.
Vacuum
Motor
Vacuum
Motor
Brush
Motor
Cord Assembly
#908086
Vacuum Switch
#911089
Brush Switch
#911089
Jumper
#911211
#1 Wht
#3 Wht
#2 Wht
Blk
Blk
Blk
Blk
Blk
Blk
Wht
Wht
Gr
Gr
Gr
Gr
Wire Conectors
(5 Locations)
#911179