17
Thresholds
When the Rescue Guardian is positioned,
and the alarm threshold(s) are “Armed” the Rescue
Guardian carries out an automatic self-calibration and saves the current physical state as a
reference point from which the thresholds activate the Visual, Audible and Mobile alarms.
For Example:
Incline
- A strut is positioned at 45 degrees, the Alarm threshold set at 2 degrees. The Rescue
Guardian is then armed. The alarm will sound if the strut moves to s 43 degrees or 47 degrees
of incline.
Load
(Selectable Units)
Incline Angle
(Degrees)
Vibration
(Hertz)
Pounds
Min 100 - Max 2300
Min 0.1
–
Max 15
1hz
–
100hz
Kilograms
Min 45 - Max 1043
Newtons
Min 444 - Max 10230