![Paratec Next Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/paratec/next/next_owners-manual_755006005.webp)
Paratec GmbH
Next H / C
Issue II
04-2005
Owner‘s Manual
5
Inspection Procedures
Carry out inspection proceedures at assembly, before every repack and after
emergency use.
According to the manufacturer‘s regulation, every NEXT rig must be inspec-
ted by qualified personel, before it is used for the first time, before every re-
pack, no matter if it was used or not and after it was handled in an improper
way such as after water jumps etc. The periodic inspection and repack cycle
for this Harness Container Sytem is 2 months. Other countries may have
different regulations, so please check with your responsible organisation.
Read the instructions in this manual completely before you begin.
Points of Inspection
Inspect for
Main lift web
damaged edges, velcro damage, broken
stitches, ravelled stitches
Reserve ripcord, ripcord pocket, cable
housing
tight fit in pocket, bent pin, enough
excess cable, worn out velcro, broken
stitches, loose tacking on MLW and / or
reserve flap
Chest and leg straps
damaged edges, velcro damage, broken
stitches, ravelled stitches, worn out ela-
stic keepers
Cutaway pad, cables, cutaway housings
velcro damage, nicks in cables, damaged
cables, dirty cables,
Container flaps
broken plastic stiffeners
Grommets
sharp edges, bad or improper setting,
AAD set up
according to manufacturer‘s installation,
damaged cables
Main riser
velcro damage, bent rings, damaged
closing loop,
hardened webbing on -ring, good togg-
le fit,
Free bag and pilot chute
grommets for sharp edges, all seams
of bag, velcro in good condition, safety
stow, bridle seams, damages on pilot
chute fabric, spring force sufficient
Main deployment bag and pilot chute
damaged grommets, old rubber bands,
retract system of P/C in good condition,
Pilot Chute fabric for porosity
Closing loops
proper length, not frayed, general conti-
tion, proper type for AAD used
Entire hardware
rust, sharp edges, cracks, correct instal-
lation
Содержание Next
Страница 12: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 12 Continue by closing the right side flap Close flap 5 ...
Страница 23: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 23 ...
Страница 24: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 24 ...
Страница 37: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 37 ...
Страница 39: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 39 ...
Страница 42: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 42 ...
Страница 43: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 43 ...
Страница 44: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 44 ...
Страница 45: ...Paratec GmbH Next H C Issue II 04 2005 Owner s Manual 45 ...