background image

Parasound

®

 ZoneMaster

 

 450 Owner’s Manual  

Page 9

 

 

Rear Panel Audio Connections 

 

Channel pairs (left and right) are grouped into two zones.  Typically each room or area is considered 
a zone but this will be determined by the system integrator. 
 

Always disconnect the AC cord to your ZoneMaster 450 before plugging in or unplugging any 
connections.

  Inserting or removing a

n interconnect cable’s plug while this power amp is turned on can 

result in a burst of sound that can damage your loudspeakers.  Make sure there is no strain or tension on 
any input cables, speaker wires, DC trigger wires or the AC cord that could cause them to pull loose. 

 

 

 

 

Audio Input Connections 

 

The Speaker Level Input Connector 

This is an additional type of audio input that can be used by Zone 1 and connected to Zone 2 by using the 
Loop Out jacks.  The Speaker Level input enables the ZoneMaster 450 to connect to any audio receiver or 
stereo system even if it lacks preamp output jacks.  This is a high impedance input and the ZoneMaster 
450

’s Speaker Level input can connect to the speaker terminals on any receiver or amplifier.  This will not 

reduce the output power or degrade the sound quality of the speakers that are already connected directly to 
the “host” receiver or amplifier.  Audio connected to the Speaker Level input connector will be routed to the 
Left and Right inputs of zone 1.  Speaker level audio is also converted to line level and routed to the zone 1 
Loop Out jacks which provide a line level output to drive zone 2 or additional amplifiers.  To route the 
Speaker Level Input to zone 2 as well as zone 1 you can use any standard RCA cables and connect it 
between the Loop out jacks and the input for zone 2. 

 

Note:

 You should connect only the RCA connections for zone 1 or the Speaker Level inputs, 

but not both or you could hear both sources at the same time. 

 

Note:

 You can detach the speaker input connector block from the 450 to make it easier to 

attach and secure the 4 speaker wires.  It accepts bare wires up to AWG 16.  Each 
wire should be twisted tightly and/or tinned with solder to prevent stray strands that 
could short circuit the amplifier.  Since the Speaker Level input consumes a small 
fraction of a watt of your receiver's power output using large gauge speaker wire 
provides absolutely no performance advantage.

 

 

 
Line Input Jacks for Channels 1 through 4 

These are standard line level audio Inputs for each channel.  Connect these jacks to the Left and Right 
output jacks on your preamp, whole-house audio controller or the zone outputs of your AV receiver.  

 

 

Содержание ZoneMaster Model 450

Страница 1: ...TM M M ZoneMaster Model 450 Universal Four Channel Amplifier Owner s Manual...

Страница 2: ...Parasound ZoneMaster 450 Owner s Manual Page 2...

Страница 3: ...e prong grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat...

Страница 4: ...Parasound ZoneMaster 450 Owner s Manual Page 4...

Страница 5: ...dealer invoice and store it inside the ZoneMaster 450 s carton If the ZoneMaster 450 should require warranty repair you will need its original carton and foam packing inserts to ship it Please do not...

Страница 6: ...Speaker Level Input Connector 9 Speaker Impedance and Paralleling Multiple Speakers 10 Rear Panel Mode Switch 11 Channel Level Controls and Uses 12 Turn On Options 13 Selecting Audio Trigger or 12V T...

Страница 7: ...k or any other enclosed space You should never install the ZoneMaster 450 in an unventilated equipment cabinet or compartment because hot air will not exhaust adequately to prevent overheating Even a...

Страница 8: ...ng Mexico as well as in Taiwan In some countries such as Brazil AC voltage varies by region Most other countries require setting this switch to 230V With the 230V setting the ZoneMaster 450 can operat...

Страница 9: ...akers that are already connected directly to the host receiver or amplifier Audio connected to the Speaker Level input connector will be routed to the Left and Right inputs of zone 1 Speaker level aud...

Страница 10: ...onnect multiple speakers to each channel This is done by simply twisting the two positive speaker wires together and connecting them to the positive speaker output on the 450 The same should be done w...

Страница 11: ...dged mode can be used to drive larger or less efficient speakers in large spaces where more power is needed A typical use of the bridged mode would be to run Zones 1 and 2 in Bridged Mode to power a s...

Страница 12: ...450 s Level controls until the volume level in the room or zone is as high as you or the home owner might ever want it to be This is the most appropriate setting for the Level controls because it will...

Страница 13: ...vent the amplifier from being turned on or off manually or by mistake Note The 12V turn on trigger circuit in the ZoneMaster 450 requires a mere 5mA from the 12V trigger source Audio Each zone can be...

Страница 14: ...nt and volume levels This also indicates a problem Both channel number indicators for a zone will always illuminate the same color Causes for the front panel indicators to illuminate red are The speak...

Страница 15: ...e channel sees only 4 ohms If two 4 ohm speakers are attached the channel sees only 2 ohms The zone may have overheated and will not resume operation until it cools down Ensure that you have provided...

Страница 16: ...re outside the Warranty Unit is not eligible for repair under the terms of the Parasound warranty if 1 Unit was not purchased from a Parasound Authorized Dealer 2 You do not have the original bill of...

Страница 17: ...50 Watts 8 Total gain 29 dB Level controls set to Maximum S N Ratio 112 dB input shorted IHF A weighted DC Trigger Requirements 9 Vdc to 12 Vdc 5 mA Audio Trigger Requirements 2 mV audio signal AC Po...

Страница 18: ...____________ ____________________________________________ ____________________________________________ ____________________________________________ ____________________________________________ _______...

Страница 19: ...Parasound ZoneMaster 450 Owner s Manual Page 19...

Страница 20: ...Parasound ZoneMaster 450 Owner s Manual Page 20 Parasound Products Inc 2250 McKinnon Ave San Francisco CA 94124 Customer Service 415 397 7100 www parasound com...