Mode Switches for Turn On and Turn Off

Turn On Switch

The Turn On switch has three positions that control how the 
Zbreeze is turned on.
•  

Man  

Manual Turn On: When this switch is set to its Man 

position the Zbreeze is switched on and off with its front 
panel Power button.

•  

AC  

Automatic Turn On: When this switch is set to its AC 

position the Zbreeze will turn on automatically when the AC 
outlet where its power cord is plugged in is turned on.

•  

12V  

Automatic Turn On: When this switch is set to its 12V position the Zbreeze will turn on 

automatically when an external 12 volt trigger voltage is applied to its 12V Trigger In jack. 

Note:

 The AC and 12V switch positions disable the front panel Power button so the Zbreeze 

turn on and off power is controlled only by the system controller. This way it can’t inadvertently 
be switched off.

12V Off Switch

The 12V Off switch has two positions which control how the 
Zbreeze turns off while its turn on switch is set to 12V.
•  

Inst

  Instant Turn Off:  When this switch is set to its Inst  

position the Zbreeze is switched off as soon as the trigger  
voltage at the 12V Trigger In jack is removed.

•  

Delay

  Delay Turn Off: When this switch is set to its Delay 

position the Zbreeze continues to operate for approximately 
10 minutes after the trigger voltage at the 12V Trigger In jack 
is removed. After a 10 minute delay it will turn itself off. This is an important feature because it 
allows equipment to cool quicker after power down.

4

Содержание Zbreeze

Страница 1: ......

Страница 2: ...ng grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the...

Страница 3: ...on 2 Applications 2 115 230v AC Selector Switch 2 Rack Mounting 3 Rear Panel Connections and Settings 4 Front Panel Controls 6 If You Require Assistance 7 Warranty Repair 7 Specifications 8 TABLE OF C...

Страница 4: ...ous operation enables the fans in the Zbreeze to run slower for quieter operation and longer life You can select the fan speed which is adequate to keep the local area from overheating It will run qui...

Страница 5: ...he Zbreeze must be mounted horizontally It occupies only half the width of a single rack space in a standard 19 equipment rack For rack mounting you can fasten it to another Parasound Z Custom model b...

Страница 6: ...e will turn on automatically when an external 12 volt trigger voltage is applied to its 12V Trigger In jack Note The AC and 12V switch positions disable the front panel Power button so the Zbreeze tur...

Страница 7: ...igger to another device It provides a convenient way to connect another component for 12V trigger operation AC Inlet Set the AC line mains voltage before you connect the Zbreeze s power cord and befor...

Страница 8: ...s Fan speed is indicated in the adjacent display window as Low Med High Note The default fan speed is Medium Maintaining Your Zbreeze Your Parasound Zbreeze requires no periodic maintenance other than...

Страница 9: ...adequate insurance to cover its value You must include a copy of your purchase receipt since this document establishes the validity of this unit s warranty Warranty repairs are only performed by Para...

Страница 10: ...50 60 Hz 1 5 watts standby 8 watts maximum fan speed Dimensions 91 2 Wide 10 Deep with connectors 2 High with feet 13 4 panel only 241 x 254 x 50mm 44 1mm panel only Net Weight 3 6 lbs 1 7 Kg Rack Mou...

Страница 11: ...NOTES Notes 9...

Страница 12: ...Rev 0 92 Parasound Products Inc 2005...

Отзывы: