Applications

The Zbreeze is designed to prevent stagnant hot air around nearby heat-producing components, 
drawing hot air away from a heat-producing component, and into the rack’s general circulating 
air. It is not intended to exhaust hot air from an entire rack or compartment full of equipment 
and should not be employed as a substitute for general rack or cabinet forced air circulation.
Temperatures can increase to dangerous levels around closely-spaced components where local 
pockets of stagnant hot air are not exhausted by the overall air circulation in an equipment rack 
or compartment. 
The Zbreeze provides extremely quiet localized cooling by drawing heat away from components 
that are installed directly above and below it. Three premium 92 mm ball-bearing whisper fans 
draw hot air into the Zbreeze through openings in its bottom. This hot air is pushed out in two 
directions, through openings in its top cover, to prevent the component above it from baking, 
and through openings in its rear panel into the general cabinet air circulation. 
The Zbreeze is designed to run continuously while your system is turned on so it does not use 
a thermostat to switch it on and off. It prevents a local “hot spot” from forming rather than  
running at high speed to cool it down after it’s already hot. Continuous operation enables the 
fans in the Zbreeze to run slower for quieter operation and longer life. You can select the fan 
speed which is adequate to keep the local area from overheating. It will run quietest on its low 
fan speed setting and least quiet on its high fan speed setting. 
Multiple Zbreezes, installed at strategic locations in the equipment rack, will prolong equipment 
life and protect your investment.
You can also place the Zbreeze directly above a free-standing power amplifier to help dissipate 
its heat and keep it running cooler. Most power amplifiers get hotter if they are driving low 
impedance speaker loads and when they’re playing for a long time at high levels. The Zbreeze 
can prevent the power amp’s thermal protection circuits from shutting it down. 

Please read this manual thoroughly before you begin installation.

Unpacking

Carefully unpack your Zbreeze and these accessories:

  Detachable AC power cord

  Two trigger wires, one with 2.5 mm sub-mini plugs, one with a 2.5mm and a 3.5mm mini plug 

Please inspect the unit now and contact your Parasound Dealer promptly if you see evidence  
of shipping damage. Save the carton and packing inserts in case you move or in the event you 
need to ship your amplifier for repair. Before you proceed, locate the serial number on the rear 
panel or underside of the unit and record it here for future reference:

INTRODUCTION

OWNERSHIP REFERENCE INFORMATION

  Parasound Serial Number:

  

  Date of Purchase:

                   /      /

  Name of Dealer:

               

  Dealer Street Address:

        

  Dealer Phone:

                  (      )      -

2

Содержание Zbreeze

Страница 1: ......

Страница 2: ...ng grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the...

Страница 3: ...on 2 Applications 2 115 230v AC Selector Switch 2 Rack Mounting 3 Rear Panel Connections and Settings 4 Front Panel Controls 6 If You Require Assistance 7 Warranty Repair 7 Specifications 8 TABLE OF C...

Страница 4: ...ous operation enables the fans in the Zbreeze to run slower for quieter operation and longer life You can select the fan speed which is adequate to keep the local area from overheating It will run qui...

Страница 5: ...he Zbreeze must be mounted horizontally It occupies only half the width of a single rack space in a standard 19 equipment rack For rack mounting you can fasten it to another Parasound Z Custom model b...

Страница 6: ...e will turn on automatically when an external 12 volt trigger voltage is applied to its 12V Trigger In jack Note The AC and 12V switch positions disable the front panel Power button so the Zbreeze tur...

Страница 7: ...igger to another device It provides a convenient way to connect another component for 12V trigger operation AC Inlet Set the AC line mains voltage before you connect the Zbreeze s power cord and befor...

Страница 8: ...s Fan speed is indicated in the adjacent display window as Low Med High Note The default fan speed is Medium Maintaining Your Zbreeze Your Parasound Zbreeze requires no periodic maintenance other than...

Страница 9: ...adequate insurance to cover its value You must include a copy of your purchase receipt since this document establishes the validity of this unit s warranty Warranty repairs are only performed by Para...

Страница 10: ...50 60 Hz 1 5 watts standby 8 watts maximum fan speed Dimensions 91 2 Wide 10 Deep with connectors 2 High with feet 13 4 panel only 241 x 254 x 50mm 44 1mm panel only Net Weight 3 6 lbs 1 7 Kg Rack Mou...

Страница 11: ...NOTES Notes 9...

Страница 12: ...Rev 0 92 Parasound Products Inc 2005...

Отзывы: