-9-

Continuous Power Output

> 135 watts RMS x 6,  20 Hz - 20 kHz,  8 

Ω 

, all channels driven

> 200 watts RMS x 6,  20 Hz - 20 kHz,  4 

Ω 

, all channels driven

Continuous Power Output - Bridged

> 350 watts RMS,   20 Hz - 20 kHz,  8 , each bridged channel, 3+4, 5+6

Current Capacity

30 amperes peak, per channel

Slew Rate

> 130 V/µsecond

Frequency Response

12 Hz - 120 kHz, +0/-3 dB

Total Harmonic Distortion

<  0.07% at full power
<  0.03% typical levels

IM Distortion

<  0.04%

TIM

Unmeasureable

Dynamic Headroom

> 2 dB

Interchannel Crosstalk

> 75 dB at 1 kHz
> 56 dB at 20 kHz

Input Impedances

50 k

Ω 

 per channel, without looping inputs 1/2 to Ch. 3/4 or Ch. 5/6

25 k

Ω 

 per channel, if looping inputs 1/2 to either Ch. 3/4 or Ch. 5/6

17 k

Ω 

 per channel, if looping inputs 1/2 to both Ch. 3/4 and Ch. 5/6

Input Sensitivity

1.0 V THX Reference Level

S/N Ratio

> 118 dB, input shorted, IHF A-weighted

Damping Factor

> 800 at 20 Hz

Dimensions

19" wide x 7" high x 18.5" deep (7 5/8" high with feet)

Weight

71 lbs. net

Special Features

Содержание HCA-1206

Страница 1: ...al from the carton Take care not to cut or scratch yourself on the exposed extruded metal heatsinks on either side of the unit Save your cartons and the packing inserts for safe transport in case you move or if the unit ever requires shipping for repair Due to the massive weight of the HCA 1206 the inner white printed carton is not strong enough for safe shipping by itself You absolutely must plac...

Страница 2: ...more linear region Although the amplifier may run a little warmer than other amplifiers we feel the resulting sonic improvements are significant and justified However to insure safe and reliable operation it is very important that the amplifier has plenty of ventilation to prevent overheating and automatic shut down from the thermal protection circuitry Please observe the following guidelines when...

Страница 3: ... CA U S A CAUTION TO PREVENT ELECTRIC SHOCK DO NOTREMOVE COVER NO USER SERVICEABLEPARTS INSIDE REFER SERVICING TOQUALIFIED SERVICE PERSONNEL Power Consumption 600 W CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Inputs Fuse 15A Power AC 120V 60Hz WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAINOR MOISTURE Mono Bridging Separate CH 3 CH 4 Loop 1 2 3 4 On Off Loop 1 2 3 4 On Off M...

Страница 4: ...gurations depending upon your needs Below are examples of four and five channel operation Input Connections for Four Channel Operation Use INPUTS 1 and 2 for your front left and right channels Use INPUTS 3 and 4 bridged mono for your center channel Connect the center output of your processor to INPUT 4 only Use INPUTS 5 and 6 bridged mono for your subwoofer Connect the subwoofer output of your pro...

Страница 5: ...ker wire will have some sort of mark either printing a raised ridge on the insulation or a different color of conductor This permits you to know which wire you had connected to the and which to the speaker terminals so you can do exactly the same at the power amplifier terminals Polarity is marked separately for both stereo and bridged connections Banana Plugs Banana plugs offer the most convenien...

Страница 6: ...rt as possible to maintain a high damping factor and avoid deteriorating bass response You may also wish to experiment with audiophile grade speaker wire and interconnects The benefits of these are debated among audio hobbyists and we cannot guarantee you will always hear an audible improvement AC Power Connections and Audiophile Grade AC Cord Before you attach the AC cord make sure the HCA 1206 p...

Страница 7: ...inate Level Controls Each channel has a separate input level control The HCA 1206 will sound best with its level controls set to maximum where they are effectively out of the audio signal path However if your preamplifier has very high gain and its volume control cannot track properly for left right channel balance near its minimum position it may be necessary to reduce the input level control set...

Страница 8: ...ou contact your authorized Parasound Dealer or Installer or call Parasound Technical Service if you suspect a problem We may be able to suggest other diagnostic tests you can easily perform yourself and which will save you a lot of trouble If it is determined that the HCA 1206 should be returned to Parasound for inspection and possible servicing you must first call or write to obtain a Return Auth...

Страница 9: ...full power 0 03 typical levels IM Distortion 0 04 TIM Unmeasureable Dynamic Headroom 2 dB Interchannel Crosstalk 75 dB at 1 kHz 56 dB at 20 kHz Input Impedances 50 kΩ per channel without looping inputs 1 2 to Ch 3 4 or Ch 5 6 25 kΩ per channel if looping inputs 1 2 to either Ch 3 4 or Ch 5 6 17 kΩ per channel if looping inputs 1 2 to both Ch 3 4 and Ch 5 6 Input Sensitivity 1 0 V THX Reference Lev...

Страница 10: ...for 220 V 240 V 50 Hz Operation The amplifier may be rewired for operation abroad This involves changing several wires on the power transformer Please refer this conversion to a skilled electronics technician to avoid personal injury or possible harm to the amplifier There are hazardous high voltages present inside the chassis even after the power is turned off and the AC cord has been disconnecte...

Страница 11: ...y This warranty becomes void if the product has been damaged by alteration misuse accident or neglect Alteration includes any removal obscuration or defacement of its serial number This warranty becomes void if unit has been connected or operated contrary to printed instructions The warrantor assumes no liability for property damage or any other incidental or consequential damage whatsoever which ...

Отзывы: