background image

High Pass Filter Switch

The High Pass filter can improve the sound in virtually any installation. It’s called a “high pass” 
filter because it permits signals higher than 20 Hz and 40 Hz to pass, while preventing signals 
below these frequencies from passing.

  The Flat switch position disconnects the filter and the 275’s frequency response is flat.

  The 20 Hz switch position filters out frequencies below 20 Hz. Your speakers have greater 

dynamic range and far less distortion when they don’t receive frequencies which are lower than 
they can reproduce. Likewise, the 275 operates more efficiently when it’s not called upon to 
amplify frequencies which the speakers can’t reproduce. Because the 20 Hz filter has a steep 
18 dB per octave slope, it is essentially a sub-sonic filter, and you probably won’t notice any 
loss of bass unless you’re using very large speakers. 

  The 40 Hz switch position filters bass below 40 Hz at 18 dB per octave. This is ideal when the 

275 is driving in-wall or in-ceiling speakers because very few of them can reproduce very much 
bass below 40 Hz. You’ll enjoy much cleaner sound and higher undistorted volume levels. Not 
having to amplify bass that’s inaudible with your speakers is another way the 275 will run cooler.

Note:

 Autoformer-type passive volume controls are highly reactive loads that are known to cause 

amplifier malfunction. The 20 Hz or 40 Hz filter settings enable the 275 to drive them with ease.

Speaker Connections

There are separate speaker terminals for two pairs of speakers, labeled Speaker Pair A and 
Speaker Pair B.
Each - and + speaker terminal will accept bare speaker wire up to AWG 12, a wire terminated 
with a 

1

4

 spade lug, or with a single banana plug; dual banana plugs which are 

3

4

 (19mm) apart 

may be used for each speaker.

If you use bare wires, remove only enough insulation, about 

1

2

 (12mm) for each exposed bare 

wire to insert through the small hole in the side of the binding post. Before inserting a bare 
wire, twist the strands tightly between your fingers to prevent strays that might touch the chas-
sis or another terminal and cause a short circuit. If you have soldering experience you may want 
to “tin” the stripped bare wire with solder for a cleaner termination and to prevent the wire 
from oxidizing.

REAR PANEL CONNECTIONS AND CONTROLS continued

5

WARNING: To Prevent Fire Or Shock Hazard,

Do Not Expose This Unit To Rain Or Moisture.

AC      115V/60Hz

AC      230V/50Hz

Speaker Pair A

L

R

Mono

Manual

Audio Sens

Max Min

12V Trigger

Ground

Lift Norm

Mono

Stereo

4-8

Ohms

2-3 

Ohms

230V

50Hz

115V

60Hz

20Hz 40Hz

Flat

Audio

Auto Turn On

Loop

Level

Bridging

In

12V

In

Loop

R

Mono

+

+

AC      115V/60Hz

AC      230V/50Hz

Power Consumption: 300W

AC

Voltage

Load

Impedance

275 Two Channel Amplifier

Parasound Products, Inc.

San Francisco, CA    U S A

CAUTION: To Prevent Electric Shock, Do Not Remove Cover. No 

User-Serviceable Parts Inside. Refer Servicing To Qualified Service Personnel.

L

High Pass Filter

Speaker Pair B

L

R

Mono

Speaker Pair A

L

R

Mono

Speaker Pair B

L

R

Mono

Содержание 275

Страница 1: ...Model 275 Two Channel Power Amplifier OWNER S GUIDE Model 275 Two Channel Amplifier A B Power M o d e l 2 7 5 T w o C h a n n e l A m p l i f i e r Protect Hi Temp L R...

Страница 2: ...will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the ground...

Страница 3: ...High Pass Filter Switch 4 Speaker Connections 5 Bridging Switch Stereo Mono 5 Mono Input 6 Speaker Connections 6 Load Impedance Switch 6 Auto Turn On 6 Sensitivity Adjust Knob 8 Ground Switch 8 Front...

Страница 4: ...thoroughly before you begin installation Unpacking Carefully unpack your Model 275 and these accessories Detachable AC power cord Trigger wire with a 2 5 mm sub mini plug at both ends Trigger wire ad...

Страница 5: ...till develop around any heat producing equipment Therefore a ventilation fan is high ly recommended Allow a few inches of empty space on each side and above the unit and try to avoid crowding or stack...

Страница 6: ...certified amplifier might play a bit louder because of its higher power output We recommend setting the 275 s R and L level controls to 3 o clock if you are driving it from a THX surround controller...

Страница 7: ...peakers is another way the 275 will run cooler Note Autoformer type passive volume controls are highly reactive loads that are known to cause amplifier malfunction The 20 Hz or 40 Hz filter settings e...

Страница 8: ...the mono power output is much higher than the sum of the L and R channel outputs for stereo operation Mono Input and Speaker Connections 1 Turn the unit off and remove the AC cord 2 Connect the single...

Страница 9: ...s set to its 12V position the Model 275 is turned on and off with an external 9V to 12V voltage from your preamp or controller When the external volt age ceases the Model 275 will turn off immediately...

Страница 10: ...gging in the 275 s AC cord for the first time will usually create an internal power surge that false triggers its Audio auto turn on even if there s no audio signal at its input jacks and it will rema...

Страница 11: ...right away You can also turn it off by unplugging its AC power cord Auto Turn On switch in the Audio position turn off the preamplifier surround controller or system controller that drives your 275 Y...

Страница 12: ...ires are secure at both ends Make sure the control preamp receiver is switched to the correct input If using Auto turn on increase the sensitivity of the audio trigger Is the Hi Temp or Protect or bot...

Страница 13: ...Dealer or Parasound Authorized Reseller Units Will Be Refused by Parasound Under the Following Conditions 1 Unit was sent without the Parasound assigned RA number marked on the carton 2 Unit was sent...

Страница 14: ...at 2 828 V output IHF A weighted 84 dB at 2 828 V output unweighted Input Impedance 33 k Input Sensitivity 800 mV for full rated output Inter Channel Crosstalk 80 dB 1 kHz 72 dB 10 kHz 65 dB 20 kHz D...

Страница 15: ...Notes CONNECTION AND SETUP NOTES 13...

Страница 16: ...why Parasound has been a quality and value favorite of magazine reviewers sound professionals and listeners like you since we were founded in 1981 rev 0 91 2005 Parasound Products Inc Parasound Produ...

Отзывы: