IMPORTANT INFORMATION REGARDING UNIT

 

 
 

This  heater  must  be  installed  to  the  requirements  of  the 
local  authorities  both  gas  and  electrical.  The  installation 
must comply with the gas installation code AG 601.

 

 

 

 
 

The  fitting of  the  transformer  and wiring  to  the  appliance 
must  comply  with  the  national  wiring  code  and  must  be 
performed by a licensed electrician.

 

 

Each  heater  must  be  fitted  with  its  own  high/low  switch 
and this switch must be isolated from all other sources

 

 

of electricity. If this is not done a hazardous situation 
could  occur.  If  more  than  1  heater  is  wired  to  the 
same high/low switch the warranty is void.

 

 

 
 

The  OZGLOW  HE  40  Hi  /  Lo  patio  heater  is  available  in 
versions for use with either Natural or Propane Gas. Gas 
pressure details and gas type are on the appliance data 
plate.

 

 

 

 
 

This  appliance  is  certified  for  outdoor  use  in  both 
residential and non-residential premises.

 

 

 

 

This  appliance  is  also  certified  for  non-
residential  indoor  use.  When  used  indoors,  the 
minimum room size is 200m3.

 

 

This appliance must only be used in a well ventilated area.

 

 

 
 

Do not place articles on or against this appliance. 
Do not use or store flammable materials near this 
appliance.

 

 

Do  not  spray  aerosols  in  the  vicinity  of  this 
appliance while it is in operation.

 

 

 

 

 
 

© PARASOL HEATERS AUSTRALIA 

+61 3 9549 4466 - Head 61 3 9546 6069

 

www.parasolheaters.com.au

 

 

Created on 24/09/2015

 

Page 4 of 18

 

Содержание OZGLOW HE40

Страница 1: ...Patio Heater Instructions OZGLOW HE 40 Hi Lo PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 61 3 9546 6069 www parasolheaters com au Created on 24 09 2015 Page 1 of 18...

Страница 2: ...d COMPONENTS 7 UNIT CLEARANCE 9 UNIT CLEARANCE PATIO RESTAURANT 10 HEATER SPACING 10 INSTALLATION INSTRUCTIONS OPTION A 11 INSTALLATION INSTRUCTIONS OPTION B 13 POINTS TO REMEMBER 15 LIGHTING INSTRUCT...

Страница 3: ...domestic or 90 day commercial limited warranty and are fully serviceable with readily available parts if required Delivery is available throughout Australia and overseas The suspended gas heater model...

Страница 4: ...d to the same high low switch the warranty is void The OZGLOW HE 40 Hi Lo patio heater is available in versions for use with either Natural or Propane Gas Gas pressure details and gas type are on the...

Страница 5: ...ly supervised when they are in the area of the appliance Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance Any guard or other protective de...

Страница 6: ...be required as necessary Keep this OZGLOW heater free of cobwebs and as dust free as possible If the flame becomes excessively long and yellow or if soot builds up on the emitter mesh turn the heater...

Страница 7: ...nging Frame Dimensions MIN 15mm GAS INLET BY INSTALLER 650mm 15mm NOMINAL BORE GAS PIPE or COPPER TUBE Overall height 950mm Overall width 960mm PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 61...

Страница 8: ...HE 40 Hi Lo DIMENSIONS and COMPONENTS Continued J Arm Dimensions 580mm MIN Straight Arm Dimensions MIN PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 61 3 9546 6069 www parasolheaters com au Cr...

Страница 9: ...f the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more tha...

Страница 10: ...shown No air heating efficiency is counted on in this installation Illustrates the same patio with a 2 5m high protective wall enclosing the patio Only six heaters are required for warmed air will rem...

Страница 11: ...tting supplied to the gas inlet of the heater and point it at 90 degrees to the front of the heater 3 Remove the socket assembly from the frame and screw the top half of this assembly to the heater us...

Страница 12: ...he emitter mesh and reflector The red and black wires on the heater are to go to the 24 VAC transformer and the yellow wires are to be run to the high low switch supplied by the installer This applian...

Страница 13: ...ough to enable joining these wires to the wires on the heater head 3 Trim the 4 wires on the heater head to a length of approximately 100 mm Enter the heater head into the top of the T piece and rotat...

Страница 14: ...ipe All wiring in the heater head is 24 VAC Refer to warnings on page 4 5 When the wires have been joined together feed the wires back up the pipe until they look as shown in this picture 6 Fit the bl...

Страница 15: ...person Test fire the heater and check the gas pressure All pressure details are on the data plate or refer to page 6 If the heater cannot be adjusted properly contact Parasol Heaters Australia This ap...

Страница 16: ...Heater Turn Power ON To Turn Heater Off Turn Power OFF Caution If heater fails to light turn power OFF for 5 minutes then turn the power ON again PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 6...

Страница 17: ...O The two yellow wires receive 24 VAC power from within the appliance When these wires are joined via a switch the heater is on high fire GAS VALVE ADJUSTMENT SCREWS DIAGRAM Pressure Test Point Low F...

Страница 18: ...rned to our factory for repair or replacement parts Parasol Heaters Australia will not cover any expenses involved in the return of a heater for a warranty repair Parasol Heaters Australia Pty Ltd wil...

Отзывы: