Paramount Fitness SDX 2 Скачать руководство пользователя страница 7

SDX2 is a circulation drain, not intended to remove debris. For this reason it is suggested SDX2 be 

installed on walls whenever possible. SDX2 is a high fl ow safety drain system submerged suction 

outlet suitable for single or multiple drain use on the wall and floor. This is to keep debris and sand 

from collecting on and around the low velocity SDX2 cover. Do not locate suction outlets on seating 

areas or on the backrest of such seating areas.

CAUTION

 - Drain covers deteriorate over time due to exposure to sunlight and pool chemi-

cals and must be replaced every five (5) years from installation (or earlier if the cover or grate 

becomes damaged in any way).

NOTICE

 - Some covers and grates are incompatible with other manufacturers’ frames and 

the existing frame must first be removed and a new supplied frame installed.

WARNING

 - The maximum flow rate for each pair of SDX2 drains varies depending on size 

and orientation of pipe and location on wall or floor. See chart below for flow limits based on 

variables. Any modification that increases the flow rate of the circulation system shall require 

reevaluation of the cover/grate and sump to ensure that the flow rating of the Suction Outlet 

Fitting Assembly (SOFA) is not exceeded. Compliance with this standard requires that these SO-

FA-configuration specific flow ratings NOT be exceeded at any time the pool is open to bathers.

Compliance with this standard requires selecting and installing a SOFA, or combination of SO-

FAs, such that the resulting individual suction system flow rating is greater than the pumping 

system’s maximum system flow rate.

The velocity at the opening to the SDX2 drain at the system flow is equal to gpm/134.648=(X)FPS. 

For multiple drain systems where more than two drains are used, the maximum flow rate is calcu-

lated per ANSI/APSP-7 Section 4.6 as shown in the following chart.

SOFA SDX2 FLOW RATINGS

Flow 

Rating

(GPM)

Pipe Size

Pipe Port 

Orientation

Drain 

Mounting 

Orientation

Flow

Rating 

(GPM)

Pipe Size

Pipe Port 

Orientation

Drain 

Mounting 

Orientation

180

3"

Side

Floor

140

3"

Side

Wall

116

2.5"

Side

Floor

108

2.5"

Side

Wall

100

2"

Side

Floor

100

2"

Side

Wall

60

1.5"

Side

Floor

60

1.5"

Side

Wall

178

3"

Bottom

Floor

140

3"

Bottom

Wall

120

2.5"

Bottom

Floor

108

2.5"

Bottom

Wall

100

2"

Bottom

Floor

100

2"

Bottom

Wall

60

1.5"

Bottom

Floor

60

1.5"

Bottom

Wall

!

!

USE ONLY PARAMOUNT GENUINE REPLACEMENT PARTS

6

USE ONLY PARAMOUNT GENUINE REPLACEMENT PARTS

Содержание SDX 2

Страница 1: ...afety Drain for Concrete Installation Manual Contents Safety Instructions 1 Introduction 3 Installation 4 Bulb Replacement 14 Troubleshooting 16 Replacement Parts 17 Warranty 19 004 027 8746 00 R04 EC...

Страница 2: ...t from hair entanglement or limb entrap ment Keep clear of pool and spa drains Hair sucked into pool or spa drains will tangle and knot trapping the swimmer under water Avoid placing your hair near a...

Страница 3: ...ing drain cover This could result in swelling of the limb and or trapping a swimmer underwater Avoid mechanical entrapment of jewelry swimsuit hair decorations finger toe or knuckle in a drain pipe wi...

Страница 4: ...following issues when designing and installing a proper filtration system Properly bond grounded pumps time clocks switches and any other metal in or near water This is required to address Electrical...

Страница 5: ...water See parts breakdown at end of this manual for specific compo nent service life notations Any SOFA component that is severely faded chalking or brittle when flexed shall be replaced even if it h...

Страница 6: ...ty The SDX2 cover and support materials are far more durable than ABS the typical plastic used in swimming pool drain covers In addition to fading the Buna in ABS is prone to UV degrada tion resulting...

Страница 7: ...l require reevaluation of the cover grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly SOFA is not exceeded Compliance with this standard requires that these SO FA co...

Страница 8: ...Wall Min Flow Rating of Each Cover Max System Flow Rate One SDX2 High Flow Safety Drain 180 gpm 681 lpm 140 gpm 529 lpm 100 Two SDX2 High Flow Safety Drains 180 gpm 681 lpm 140 gpm 529 lpm 100 Three...

Страница 9: ...Disable the Single Outlet provided the system piping and skimmer s shall be capable of handling the full system flow and minimum turnover rates are achieved Installation NOTICE The pipe size must to a...

Страница 10: ...d the suction pipe which ring does not have threaded screw hole inserts or the pool or spa surface has an indented sump without threaded screw hole inserts and the distance between the pool or spa sur...

Страница 11: ...the handle of wire strippers cut screw to the correct length 3 Install screw through the support plate into the sump until the support plate is snug to the pool surface and there is no gap behind the...

Страница 12: ...trimmed flush for the part to fit snugly in the support plate WARNING FAILURE TO PROPERLY INSTALL THE PLUGS COULD DISABLE THE SAFETY FEA TURES OF THE SDX2 RETRO Fig 10 5 Attach the drain cover to the...

Страница 13: ...ONLY PARAMOUNT GENUINE REPLACEMENT PARTS 12 Fig 11 Trim tabs flush to fit in support plate Fig 10 Attached without spacers and threaded inserts Attached with both spacers and threaded inserts A B Fig...

Страница 14: ...cludes Screws Trim Pack TORX Wrench T 25 Security Replace cover within 5 installed years Please indicate your color choice by placing the appropriate color code in place of the XX at the end of the pa...

Страница 15: ...USE ONLY PARAMOUNT GENUINE REPLACEMENT PARTS 14...

Страница 16: ...tries Inc 2023 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliated with or endorsed by those third parties...

Отзывы: