OPERATIONS
9
TO TURN ON THE HEATER
A.Turn on the valve on the gas supply cylinder completely.
B.Press lightly and turn the variable control knob to PILOT position.
C.Press down the variable control knob and hold for 30 seconds. While holding down the
variable control knob, press the igniter button several times until the pilot flame lights. Release
the variable control knob after the pilot flame lights.
D.Press lightly and turn the variable control knob to LO (minimum) position and leave it there
for about 5 minutes, then turn the variable knob to switch to desired temperature position.
Note:A 5-minute complete shut off period is necessary before relighting.
If you experience any ignition problem please consult "Troubleshooting" on page 11.
Caution:
Avoid inhaling fumes emitted from the heater's first use. Smoke and odor from the
burning of oils used in manufacturing will appear. Both smoke and odor will dissipate after
approximately 30 minutes. The heater should NOT produce thick black smoke.
Note:
The burner may be noisy when initially turned on. Turn the knob to the level of heat
desired.