9
Fig. 13
NOT TO SCALE
WATER LINE
WATER LINE
2" PIPE
2" PIPE
3/4" PIPE
3/4" PIPE
3/4" PIPE
4. OPTIONAL SUBMERGED EQUIPMENT
INSTALLATION
(Fig. 14)
To complete this installation option you will need a two
way valve not included.
4.1 Install the two way valve on the inlet pipe to
the pump suction. (before the standpipe if
installed)
4.2 Make all other connections before the two way
valve.
4.3 Make tubing connections to the pump pot or
standpipe as in standard pump above water
level installation.
4.4 Start the pump with the valve fully open.
4.5 Note the filter pressure. Then close the valve
slightly until the pressure on the filter drops two
or three psi.
4.6 Go to setting the airflow on page 13 to
finish setting airflow. The slight restriction this
creates on the pump is the same as if it was
set at approximately one foot above water level
and allows the pump to draw air in at the pump
pot or standpipe.
(Fig. 14)
5. Lay the 3/8 tubing along desired route to the
compression fitting on the combination needle valve
flow meter on the Clear O3 unit.
6. Connect the tubing to the compression fitting. (Fig.
15)
7. Use the provided wires ties to tie the loose tubing to
the conduit or plumbing. (Fig. 16)
WATER LINE
TO SKIMMER
TO MDX
CLEAR O3
3-WAY VALVE
2-WAY VALVE
*NOT TO SCALE*
2-WAY VALVE
3/4" PIPE
2" PIPE
WATER LINE
CLEAR O3
Fig. 14
Fig. 15
Fig. 16