’17.06

P p r i n t m a k i n g :  

Haru Inc. 

Contact us (see "Contact Information" as shown below).

Dispose of the product in accordance with local laws and regulations. Contact us (see "Contact

 

Information"

 

as shown below) for any queries.

PT. Paramount Bed Indonesia 

MM2100 Industrial Town, Block M-1-1 

 

 

 

Cikarang

 

Barat

 

Bekasi

 

17520,

 

Jawa Barat, Indonesia

Tel: 

 

+62-(0)21-8981051

FAX:  +62-(0)21-89981611 

Questions regarding after-sales service

Disposal

Location in Indonesia

SPECIFICATIONS

Contact Information
For any queries, contact to the address or telephone number listed below.

[Location in THAILAND]

Others

Paramount Bed (Thailand) Co., Ltd.

Talomsin Building, 5th 

 924 Rama3 Road,

Yannawa, Bangkok 10120, Thailand

Tel :+66-2682-8072

Fax:+66-2682-8073

PARAMOUNT BED CO., LTD

Global Business Div.

14-5 2-Chome Higashisuna, Koto-ku,

Tokyo,136-8670 Japan

Tel :+81-(0)3-3648-2961

Fax:+81-(0)3-3648-2420

Product name

Model No.

Overall Length

Overall Width

Thickness

Weight

Model No.

Overall Length

Overall Width

Thickness

Weight

Type 910

Type 830

Materials

Cover

Padding

Usage environment

Storage environment

Everfit Light

PE-9002

PE-9102

PE-9012

PE-9112

1910mm

2000mm

910mm

910mm

910mm

910mm

90mm

150mm

90mm

150mm

6.8kg

9.8kg

7.1kg

10.2kg

PE-9001

PE-9101

PE-9011

PE-9111

1910mm

2000mm

830mm

830mm

830mm

830mm

90mm

150mm

90mm

150mm

6.2kg

8.9kg

6.5kg

9.3kg

Polyester with polyurethane film laminated

(MRSA Anti-bacterial, Fire retardant, Water proof)

Urethane foam

Double-layer

Triple-layer

Double-layer

Triple-layer

Temperature : Up to 50

0

C, Humidity : Under 90% Rh

Temperature : Up to 50

0

C, Humidity : Under 90% Rh

Содержание Everfit Light PE-9002

Страница 1: ...re it in a place that can be easily accessed for later reference Some of the descriptions in this instruction manual may differ from the product that you have purchased due to model Some of the descri...

Страница 2: ...ure when the mattress is used in health care centers facilities for the elderly as well as at home during recuperation In addition the firm fit side has an appropriate firmness to securely support the...

Страница 3: ...ts adhering to its surface could cause the padding to become stained as well which could trigger the spread of infectious dis ease and other healthcare threats Wipe away any dirt blood or other contam...

Страница 4: ...et inside causing the padding to deteriorate Be careful with the fastener pull tab There is a risk of hands feet or other body parts getting scraped resulting in injury Tuck the pull tab for the faste...

Страница 5: ...are completed fluids and contaminants may get inside causing the padding to break down Try to limit the amount of time that the bed is used with the back raised Using the bed with the back raised for...

Страница 6: ...bed is someone who sweats excessively In addition make sure to use a mat tress pad and wash or change the sheets and mattress pad and clean the mattress frequently as outlined in the cleaning procedur...

Страница 7: ...tress is not planned for use for ex tended periods of time 1 Do not stack other materials on the mattress 2 Avoid storing the mattress in a location exposed to high temperatures or humidity in a dusty...

Страница 8: ...ailand Tel 66 2682 8072 Fax 66 2682 8073 PARAMOUNT BED CO LTD Global Business Div 14 5 2 Chome Higashisuna Koto ku Tokyo 136 8670 Japan Tel 81 0 3 3648 2961 Fax 81 0 3 3648 2420 Product name Model No...

Отзывы: