READ
BS1 BS2 BS2e BS2sx BS2p
READ
Location, Variable
Function
Read value at Location in EEPROM and store the result in result in Variable.
•
Location
is a variable/constant/expression (0 – 255 on BS1, 0 – 2047
on all other BASIC Stamps) that specifies the EEPROM address to
read from.
•
Variable
is a variable (usually a byte) where the value is stored.
Quick Facts
BS1
BS2, BS2e, BS2sx
BS2p
Range of
EEPROM
locations
0 to 255
0 to 2047
0 to 2047
(see notes below)
Special
notes
n/a
READ only works with
current program slot on
BS2e and BS2sx.
READ works with any
program slot as set by
the STORE command.
Explanation
The EEPROM is used for both program storage (which builds downward
from address 255 on BS1, 2047 on all other BASIC Stamps) and data
storage (which builds upward from address 0). The READ instruction
retrieves a byte of data from any EEPROM address and stores that byte in
Variable. Any location within the EEPROM can be read (including your
PBASIC program's tokens) at run-time. This feature is mainly used to
retrieve long-term data from EEPROM; data stored in EEPROM is not lost
when the power is removed.
The following READ command retrieves the value at location 100 and
stores it into the variable called Result:
SYMBOL Result = B0
READ 100, Result
--or--
Result VAR BYTE
READ 100, Result
1
2
e
2
sx
2
p
2
1
NOTE: Expressions are not
allowed as arguments on the BS1.
A
SIMPLE
READ
COMMAND
.
1
2
e
2
sx
2
p
2
Table 5.67: READ Quick Facts.
Содержание BASIC Stamp 1
Страница 1: ...BASIC Stamp Programming Manual Version 2 0c...
Страница 30: ...Introduction to the BASIC Stamps Page 28 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 34: ...Quick Start Guide Page 32 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 90: ...BUTTON BASIC Stamp Command Reference Page 88 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 118: ...END BASIC Stamp Command Reference Page 116 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 128: ...FREQOUT BASIC Stamp Command Reference Page 126 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 196: ...NAP BASIC Stamp Command Reference Page 194 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 206: ...OWIN BASIC Stamp Command Reference Page 204 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 214: ...OWOUT BASIC Stamp Command Reference Page 212 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 216: ...PAUSE BASIC Stamp Command Reference Page 214 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 226: ...POLLMODE BASIC Stamp Command Reference Page 224 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 232: ...POLLOUT BASIC Stamp Command Reference Page 230 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 236: ...POLLRUN BASIC Stamp Command Reference Page 234 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 240: ...POLLWAIT BASIC Stamp Command Reference Page 238 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 262: ...RCTIME BASIC Stamp Command Reference Page 260 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 274: ...RUN BASIC Stamp Command Reference Page 272 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 310: ...SEROUT BASIC Stamp Command Reference Page 308 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 324: ...STOP BASIC Stamp Command Reference Page 322 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 340: ...ASCII Chart Page 338 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 342: ...Reserved Words Page 340 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Страница 346: ...Conversion Formatters Page 344 BASIC Stamp Programming Manual 2 0b www parallaxinc com...