background image

 

 

14 

 
 
 

We feel that our 12 hour program ( No. 3 ), which is permanently programmed into your 

controller, is the best and most useful program for the average casting operation. You can load 
your furnace at 3 - 4 or 5:00 P.M. in the evening and arrive at 7 - 8 or 9:00 A.M. and cast. Many 
casters prefer to load and cast in a 8 hour workday. We also have a 5 hour program (No. 2) that has 
worked well for many years with flasks no larger than 4" to 5". Also, you have the option of 
creating your own custom programs into the programmer (up to 6 different programs). This is 
discussed on pages 11, 12 and 13. 
 

Again, during the first hour of all programs the operator should be in attendance to remove 

the melted wax from the wax tray which you should have on the floor of your furnace. This will do 
two things. First, it will eliminate the odors and fumes created from the wax elimination, and 
second, extend the life of the heating elements. The ventilation hole(s) at the top of the furnace 
must remain open during this hour. After emptying wax from tray, replace the flasks with the sprue 
hole up, or use our WWR13 or WWT18 Grate & Tray, then leave sprue hole down. 
 

After burnout is complete, casting can be done. Once casting is complete, turn off furnace 

by pressing STOP button. If you have not completed casting by the end of the final holding time, 
the programmer will turn off. 
 

 
 
 

PROGRAMMING A DELAY FIRING [ dELA ] 

 

Regardless of the program that you run (either built-in or custom), you can insert a delay 

period before the firing profile begins. This will allow you schedule the start of the program such 
that you can cast upon your arrival. The only requirement is to have eliminated the wax either by 
the furnace with PROGRAM NO. 1 or by Steam Wax Elimination. 
 

Upon entering the desired program you are going to run (either permanent or custom) and 

 you reach the final step of displaying [ IdLE ], press DELAY START (3). The display will alternately 
show  
[ dELA ] and [ 00.00 ]. At this time you enter the amount of delay time you wish before the furnace 
begins the burnout cycle (EXAMPLE: You program at 4:00 P.M. and you want a 5 hour burnout 
(PROGRAM NO. 2) and you wish to cast at 8:00 A.M. - The delay entered is 11 hours [ 11.00 ] - This 
starts the furnace at 3:00 A.M. and you are ready to cast at 8:00 A.M.). You can enter a delay start 
time up to 99 hours. 
 

After entering your delay start time press ENTER twice. After doing so, you can see the 

timer in operation and counting down until the delay time entered has expired and the furnace 
begins the selected burnout program. 

Содержание W13

Страница 1: ...naces With Computerized Programmable Controllers W13 W14 W18 And WTNFII 10 19 Furnaces Manufactured by Paragon Industries Inc 2011 S Town East Blvd Mesquite Texas 75149 800 876 4328 972 288 7557 Fax 972 222 0646 paragonind worldnet att net www paragonweb com ...

Страница 2: ... start the burnout program All furnaces and controllers are warranted for one year against defects in workmanship or material WW ELECTRIC BURNOUT FURNACES All of our WW Electric Burnout Furnaces feature industrial quality construction and sizes to fit every shop They offer the simplest most efficient and reliable means of burnout for the lost wax caster All of these furnaces are enclosed in troubl...

Страница 3: ... s from beneath the grate at the end of the wax elimination cycle and proceed with burnout you have removed 90 or more of the cause of offensive odor and air pollution The grate is cast iron like a cook stove burner for strong support and long life Grates and trays are sized to fit standard electric burnout furnaces N0 WWT13 GRATE TRAY FIT NOS W13 W14 FURNACES 12 X 12 X 1 H NO WWT18 GRATE TRAY FIT...

Страница 4: ...emember All programming including permanent programs begins from ldLE 7 Now refer to Permanent Program No 1 page 10 This is the wax burnout program which is 1 1 hours in length and a good system check for your controller Your furnace is ready for use and you have two more permanent programs available Programs No 2 and No 3 One of these should be suitable for your use If not you may refer to PROGRA...

Страница 5: ...rilled CAUTION DO NOT DRILL INTO HEATING ELEMENT BE SURE THAT NO METAL IS IN CONTACT WITH THERMOCOUPLE METAL PARTS 4 Insert furnace line cord into socket on side of programmer NOTE 120V and 240V PLUGS COME IN MANY STYLES IF YOUR PLUG DOES NOT MATCH THE SOCKET IT MUST BE REPLACED WITH ONE THAT DOES FIT Your Computerized Programmer is rated for a maximum of 20 Amps 5 Insert programmer line cord into...

Страница 6: ...rmocouple sensor located in upper center of back wall When stacking flasks be sure that the sprue hole is exposed at all times so that no wax residue can be trapped See illustration below Flasks may touch edges not sides of each other as shown as long as the sprue holes are exposed After the wax elimination cycle is complete the flasks must be removed so that the wax tray can be removed then the f...

Страница 7: ...n alarm temperature or when the alarm is sounding during a firing To stop an alarm press any key except STOP If the alarm goes off when you first begin firing it is because it was set for a lower temperature than the present temperature Bad Program This message appears when a Ramp Hold firing has been programmed with 0 rate in the first segment Configuration This is an option that shows the factor...

Страница 8: ...hange per hour is maximum Temperature Hold When this message appears during Ramp Hold programming it is asking you if you want to hold or maintain the target temperature of that segment If so enter the length of hold time in hours and minutes i e 1 hour 20 minutes 01 20 The number after Hd is the segment number Each segment in a Ramp Hold firing is numbered starting with 1 Temperature Hold When th...

Страница 9: ...overfire On the other hand if you have a Type K thermocouple Type S selected would underfire your kiln The Type K thermocouple is standard on most kilns Safety This is the maximum temperature the Sentry is programmed for your kiln It can be altered only at the factory Skip Segment If you press the Skip Segment key during a firing SKIP will appear If you press the key again the firing will skip to ...

Страница 10: ...F FURNACE DANGEROUS VOLTAGE DO NOT TOUCH HEATING ELEMENTS WITH ANYTHING DISCONNECT FURNACE BEFORE SERVICING NOT FOR HOUSEHOLD USE KEEP UNSUPERVISED CHILDREN AWAY TIME AND TEMPERATURE DISPLAY During time display a center display period appears During temperature display the period disappears The center display period separates hours from minutes EXAMPLE 1 hour and 30 minutes displays 01 30 NOTE THI...

Страница 11: ...Apply power ldLE alternating with current furnace temperature 2 Press 1 PROG alternating with EL 3 Press ENTER ldLE alternating with current furnace temperature Program saved 4 Press ENTER STRT The furnace starts firing cycle WAX ELIMINATION Most injection waxes will become liquid at 200 F 93 C or less However some pattern waxes and plastics melt as high as 350 F 176 C and plastics burn out at up ...

Страница 12: ...ace will continue to operate at 900 F until 8 hours has passed and then shut off automatically The display will show CPLt FLASK TEMPERATURE FOR CASTING We have used 900 F 480 C as casting temperature for the flask This temperature is suitable for most castings however many casters prefer other temperatures This setting is governed by experience You may use any casting temperature you wish by enter...

Страница 13: ... slowly rising temperature from ambient to 1350 F 730 C which requires approximately 8 hours The program then holds that temperature for 2 hours and then reduces to a casting temperature of 900 F 480 C and holds for 5 hours Total time is 15 to 16 hours depending upon your load in the furnace ENTER PROGRAM NO 3 12 Hr AS FOLLOWS ACTION DISPLAY 1 Apply Power ldLE alternating with current furnace temp...

Страница 14: ...te casting can be done Once casting is complete turn off furnace by pressing STOP button If you have not completed casting by the end of the final holding time the programmer will turn off PROGRAMMING A DELAY FIRING dELA Regardless of the program that you run either built in or custom you can insert a delay period before the firing profile begins This will allow you schedule the start of the progr...

Страница 15: ...mperature to 900 F 480 C for our casting temperature We will program a 14 hour hold time for this temperature in case the operator is not ready to cast at the end of the 8 hour period NOTE YOU CAN PROGRAM ANY FLASK CASTING TEMPERATURE YOU WISH WE FIND THAT 900 F IS A GOOD TEMPERATURE FOR CASTING 14K YELLOW GOLD IN MOST INSTANCES DELAY START You can also delay the start of the program if you wish s...

Страница 16: ...ME HD In other words furnace temperature can be brought up from ambient to 300 F in 15 minutes or over a period of several hours This is governed by the RATE rA To figure the HEATING RATE 3 variables must be considered 1 The ending temperature desired 2 The starting temperature 3 The length of time that this rate should take For example If we want to heat a 300 F furnace to 1350 F over a 6 hour pe...

Страница 17: ... segment 13 Press 1350 1350 This is the temperature for the second burnout 1350 F 14 Press ENTER Hd 2 The programmer is asking for how long you want to hold 1350 F 15 Press 200 02 00 Two hours at 1350 F 16 Press ENTER rA 3 The programmer is asking for the 3rd segment rate of temperature increase or decrease 17 Press 450 0450 450 F per hour cooling down 18 Press ENTER F 3 The programmer is asking f...

Страница 18: ...nd minutes such as 3 hours and 45 minutes is 345 your display will show 03 45 and the press ENTER The display will then alternately display dELA and the time remaining for the delay WARNING NEVER LEAVE YOUR FURNACE UNATTENDED NEAR THE END OF A FIRING WE CANNOT GUARANTEE YOUR FURNACE AGAINST OVERFIRING EVEN THOUGH THE CONTROLLER IS AUTOMATIC THE OPERATOR ASSUMES FULL RESPONSIBILITY FOR TURNING THE ...

Страница 19: ...rrP appears after an extended power failure In addition after an extended power failure the controller will sound a steady alarm When ErrP appears on the display press ENTER The hours fired and furnace temperature reached at the time of the power failure will be displayed Then ldLE will display See the TROUBLE SHOOTING section of your instructions for causes STEAM WAX ELIMINATION We highly recomme...

Отзывы: