SECTION FIVE Appliance Data
NATURAL GAS
Gas Type:
CATEGORY I 2 H
Gas Pressure:
20 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input:
5.5 kW Gross (Max.)
2.4 kW Gross (Min.)
NOx Classification ………………. 5
Injectors:
Mk 360
Oxy pilot:
9079
Gas Connection:
8mm compression: semi-rigid or rigid
Data Badge Location:
Located on the left hand side of the base of the appliance behind
the trim.
Battery
9 v (1604G 6F22)
NOTE: The efficiency of this appliance has been measured as specified in BS 7977-1 2009 and the
result is 74.1% natural gas. The gross calorific value of the fuel has been used for this efficiency
calculation. Gastec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating