Table 2.
Synchronous Data Port Options (2 of 2)
Port (DTE) Initiated Loopbacks
Possible Settings: Disable, DTLB, DCLB, Both
Default Setting: Disable
Allows the initiation and termination of a local Data Terminal Loopback (DTLB) or
remote Data Channel Loopback (DCLB) by the DTE connected to this port. (DTLB is
equivalent to a V.54 loop 3, and DCLB is equivalent to a V.54 loop 2.) Control of these
loopbacks is through the DTE interchange circuits as specified by the V.54 standard.
Table 3.
Copy Ports Options
From: Port
Possible Settings: 1, 2, 3, 4
Default Setting: 1
Controls the source of the configuration options.
To: Port
Possible Settings: 1, 2, 3, 4, All
Default Setting: 2
Controls the target of the configuration options.
NOTE:
Peer IP Address and Circuit Identifier are
not copied.
Table 4.
System Options
DSL Mode
Possible Settings: LTU, NTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
NOTE:
Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows user-initiated tests to end automatically. The feature should be enabled when the
unit is remotely managed, so that control can be regained after a test is accidentally
executed.
NOTE:
Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Test Duration (min) option appears when Test Timeout is enabled.