Traps
B-3
8000-A2-GB26-00
May 1998
Event
Trap # – MIB *
Comment
Trap Class
xDSL test start
normal
Test started by any
means.
6–dsl
xDSL test clear
normal
Test over.
106–dsl
DHCP filter security failure
minor
Can not add new
route to route table
because maximum
number of stored
rules reached.
11–dhcp
SN device mismatch
minor
SN identified on port
N does not match
device described in
port configuration
role.
07–dsl
SN device mismatch clear
minor
SN identified on port
N now matches
device described in
port configuration
table.
107–dsl
SN loss of power
minor
Card received “last
gasp” message from
SN, followed by a
link down condition
one minute later.
17–dsl
SN device failure
major
Operating software
has detected an
internal device
failure. The SN is still
operating.
18–dsl
SN selftest failure
minor
Failure of the SN’s
hardware
components. This
trap is only sent if
the hardware failure
still allows sending
traps.
19–dsl
SN fatal reset
—-
Variable binding field
contains device
failure code.
20–dsl
Dynamic filter injection
failure
warning
Cannot inject or
delete dynamic filters
to SN on port N.
10–dhcp
* MII = MIB ll, ent = Entity MIB, dsl = hotDSL Enterprise MIB, sys = hotSys Enterprise
MIB, dhcp = DHCP Enterprise MIB, diag = hot_diag.mib
Содержание HOTWIRE 8310 MVL
Страница 1: ...HOTWIRE DSLAM FOR 8310 MVL AND 8510 DSL CARDS USER S GUIDE Document No 8000 A2 GB26 00...
Страница 6: ...Contents iv 8000 A2 GB26 00 May 1998 This page intentionally left blank...
Страница 10: ...About This Guide viii 8000 A2 GB26 00 May 1998...
Страница 18: ...Hotwire DSLAM System Description 1 8 8000 A2 GB26 00 May 1998...
Страница 42: ...Configuring the Hotwire DSLAM 4 8 8000 A2 GB26 00 May 1998...
Страница 84: ...Diagnostics and Troubleshooting 7 10 8000 A2 GB26 00 May 1998...
Страница 88: ...Download Code and Apply Download A 4 8000 A2 GB26 00 May 1998...
Страница 92: ...Traps B 4 8000 A2 GB26 00 May 1998 This page intentionally left blank...