March 1999
Connecting to the Network
Procedure
To connect your unit to the network:
1. Connect one end of the supplied network cable into the rear panel DSL jack.
Connect the other end to your DSL network interface.
NOTE:
Do
not use a flat VF network cable as this may severely degrade the
performance of the termination unit. Use only Cat 5 twisted-pair network
cable.
Connecting to the DTE
The Hotwire 7975 Standalone Termination Unit connects to Data Terminal
Equipment (DTE) using a 25-pin EIA-530-A interface. Depending on the cable
used, the interface can be adapted to an X.21, RS449, or V.35 interface. See the
User’s Guide for more information.
Ferrite Choke
Procedure
To install the ferrite choke onto the DTE cable:
1. Open the ferrite choke and place it around the cable as close to the cable
connector as possible.
2. Close the two halves around the cable and snap the choke shut, pressing
down on the plastic latch to secure it in place.
3. Add a tie wrap (not included) as shown to prevent the ferrite choke from
slipping down the cable.
97-14820-02
Ferrite Choke
Plastic
Latch
Connector
End
Tie
Wrap
CAUTION:
All ferrite chokes that are supplied must be installed following these
instructions to ensure compliance with FCC Part 15, VCCI, and
CISPR22 rules.