background image

 18

Table 6.

Communication Port Options (2 of 2)

Port Access Level (Terminal Use Only)

Possible Settings: AdministratorOperator
Default Setting: Administrator

Specifies the highest level of access allowed when accessing an ATI session through
a Telnet session.

Inactivity Timeout (Terminal Use Only)

Possible Settings: Enable, Disable
Default Setting: Disable

Provides automatic logoff of a Telnet session.

Disconnect Time (Minutes) (Terminal Use Only)

Possible Settings: 1 – 60
Default Setting: 5

Number of minutes of inactivity before the session terminates automatically. Timeout
is based on no keyboard activity.

Table 7.

Telnet Session Options (1 of 2)

Telnet Session

Possible Settings: Enable, Disable
Default Setting: Enable

Specifies if the unit will respond to a Telnet session request from a Telnet client on an
interconnected IP network.

Telnet Login Required

Possible Settings: Enable, Disable
Default Setting: Disable

Specifies whether a user ID and password are required to access to the ATI through
a Telnet session. Login IDs are created with a password and access level.

Session Access Level

Possible Settings: Administrator, Operator
Default Setting: Administrator

The Telnet session access level is interrelated with the access level of the Login ID.

Inactivity Timeout

Possible Settings: Enable, Disable
Default Setting: Disable

Provides automatic logoff of a Telnet session.

Содержание Hotwire 7974

Страница 1: ...Hotwire DSL MVL Systems Select the following document 7970 A2 GB20 Hotwire 7974 7975 7976 7984 7985 and 7986 Standalone Termination Unit User s Guide To request a paper copy of a Paradyne document Wit...

Страница 2: ...tions Messages and troubleshooting Technical specifications Cables connectors and pin assignments Connecting Power to the Unit If your package includes a power pack Plug the power pack into an ac outl...

Страница 3: ...To use the dc power cable 1 Connect the green wire to a suitable ground 2 Connect the orange wire to the 24 Vdc source 3 Connect the white wire to the return 4 Cut the black red and blue wires off at...

Страница 4: ...to an X 21 RS 449 or V 35 interface 7976 7986 The G 703 interface is either two BNC connectors Transmit and Receive for a 75 ohm unbalanced interface or an RJ48C 8 position unkeyed modular connector f...

Страница 5: ...ttern in progress No tests in progress Self test in progress DSL Green On Off Slow Cycling Fast Cycling DSL link is up The DSL link is down DSL training in progress An OOF condition DSX 1 DTE G 703 Gr...

Страница 6: ...your unit to a system terminal 1 Connect the 9 pin end of the terminal cable into a COM port on your PC 2 Plug the other end into the modular jack on the rear panel 3 Set the communication parameters...

Страница 7: ...nication Port Management and Communication Change Identity Administer Logins Download Code Apply Download Reset AutoRate Device Tests Abort All Tests 99 16496 Reset Device Network General SNMP Managem...

Страница 8: ...Unit Using the Configuration Menus Use the Configuration menu to select display or change configuration option settings NOTE The 79xx Standalone Termination Unit is shipped configured as an NTU If yo...

Страница 9: ...gurations from a TFTP server Configuration Edit Display The Configuration Edit Display screen is displayed when the current customer or default configuration is loaded To access the Configuration Edit...

Страница 10: ...le 7 Communication Protocol Options Table 8 General SNMP Management Options Table 9 SNMP NMS Security Options Table 10 SNMP Traps Options Table 11 Management support of the unit through SNMP and Telne...

Страница 11: ...gs depends on model 64 128 192 256 320 384 448 512 576 640 704 768 832 896 960 1024 1088 1152 1216 1280 1344 1408 1472 1536 1600 1664 1728 1792 1856 1920 1984 2048 Default Setting Highest multiple of...

Страница 12: ...gnal over a given distance Send AIS on Network Failure Possible Settings Enable Disable Default Setting Enable Specifies the action taken on the signal transmitted to the DSX when a valid signal canno...

Страница 13: ...rce configuration option or an external clock provided by the DTE connected to the synchronous data port If an external clock is used it must be synchronized to the same clock source as the LTU Invert...

Страница 14: ...or remote Data Channel Loopback DCLB by the DTE connected to this port DTLB is equivalent to a V 54 loop 3 and DCLB is equivalent to a V 54 loop 2 Control of these loopbacks is through the DTE interc...

Страница 15: ...4 Specifies the framing format to be used by the G 703 interface Time Slot 16 Possible Settings Signaling Data Default Setting Signaling Specifies whether the G 703 interface is used for voice or data...

Страница 16: ...ained after a test is accidentally executed Test Duration min Possible Settings 1 120 Default Setting 10 Number of minutes for a test to be active before automatically ending Telco Initiated Loopback...

Страница 17: ...Settings 7 8 Default Setting 8 Determines the character length of the communication port Parity Terminal Use Only Possible Settings None Odd Even Default Setting None Specifies the parity of the comm...

Страница 18: ...eyboard activity Table 7 Telnet Session Options 1 of 2 Telnet Session Possible Settings Enable Disable Default Setting Enable Specifies if the unit will respond to a Telnet session request from a Teln...

Страница 19: ...e Subnet Mask Default Network Destination Possible Settings None COM DSL Default Setting None Specifies where the default management network is connected For example if your default network is connect...

Страница 20: ...the name of the community allowed to access the unit s MIB The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB Name 1 Access Possi...

Страница 21: ...ernet Protocol address used to identify each SNMP trap manager Access Level Possible Settings Read Read Write Default Setting Read Determines the access level allowed for an authorized NMS when IP add...

Страница 22: ...Setting Disable Determines if SNMP traps are generated for enterprise specific events Link Traps Possible Settings Disable Up Down Both Default Setting Both Determines if SNMP traps are generated for...

Страница 23: ...uipment If you are not sure of the proper static control precautions contact your nearest sales or service representative Procedure To configure the unit using internal Switchpacks S1 and S2 1 Power o...

Страница 24: ...Use the following illustration to locate Switchpacks S1 and S2 on the circuit board 98 16073a Switchpack S1 S2 Front S2 Rear S1 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 Hotwire Standalone Termination Un...

Страница 25: ...s primary timing source Only valid for units configured as LTU OFF Internal Clock ON External Clock 4 Control the unit s T1 line coding OFF B8ZS ON AMI 5 Control the unit s framing format OFF ESF ON D...

Страница 26: ...the unit Refer to Table 19 If AutoRate is enabled DSL Line Rate represents the AutoRate ceiling 000 all Off 1552 kbps 6 Control whether Telco loopbacks are supported OFF Enabled ON Disabled 7 Control...

Страница 27: ...Internal clock ON External Clock 4 5 6 7 8 Control Sync Port Data Rate refer to Table 15 Selectable Payload Rates NOTE Switches 4 through 8 are only used when the unit is configured as an LTU and Auto...

Страница 28: ...kbps 1280 kbps 20 x 64 ON OFF ON OFF OFF 1552 kbps 1216 kbps 19 x 64 ON OFF OFF ON ON 1552 kbps 1152 kbps 18 x 64 ON OFF OFF ON OFF 1552 kbps 1088 kbps 17 x 64 ON OFF OFF OFF ON 1552 kbps 1024 kbps 16...

Страница 29: ...efer to Table 19 If AutoRate is enabled DSL Line Rate represents the AutoRate ceiling All OFF 2064 1040 for 1 Mbps units 6 Control enabling and disabling of the Elastic Store feature OFF Elastic Store...

Страница 30: ...ON 75 Ohm 3 Select the unit s primary timing source Only valid for units configured as LTU OFF Internal Clock ON External Clock 4 Control the unit s E1 line coding OFF HDB3 ON AMI 5 Not used 6 Enable...

Страница 31: ...FF Fixed Rate ON AutoRate Enabled 3 4 5 Select one of eight preset DSL line rates refer to Table 19 If AutoRate is enabled DSL Line Rate represents the AutoRate ceiling All OFF 2064 6 7 Not used 8 Eme...

Страница 32: ...ch Position 5 4 3 DSL Line Rate OFF OFF ON 144 kbps Supported only if 7975 or 7985 is the LTU OFF ON OFF 272 kbps Supported only if 7975 or 7985 is the LTU OFF ON ON 400 kbps ON OFF OFF 528 kbps ON OF...

Страница 33: ...his product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the customer 7 When installed in the final configuration the...

Страница 34: ...re expressly approved by Paradyne Corporation WARNING To Users of Digital Apparatus in Canada This Class A digital apparatus meets all requirements of the Canadian interference causing equipment regul...

Отзывы: