Customizing V.35-Compatible Units
5-2
7925-A2-GB20-30
PRELIMINARY DRAFT
June 1997
The “G123” code indicates that the unit powered up successfully.
Enter “?” to redisplay the menu.
This guide depicts the system terminal menus as they appear from a unit
configured for use on the CP side of an HDSL connection. This is the default
configuration for Model 7925 units. The Main Menu for a unit configured for use
on the CO side is identical, except that option 7 is HTUR Menu.
Making Changes from the Terminal Interface
The Board Configuration menu displays the current board software and hardware
settings. It also allows you to change certain parameters on the board.
This function is affected by the status of the switchpack (DIP switch control)
setting.
When operating in Terminal Mode (the system default) you can make
configuration changes through the terminal menus.
When operating in Switchpack Mode, you can display configuration
parameters using the terminal menus, but any configuration changes must be
made using the switchpacks and jumpers on the board hardware. Refer to
Making Changes in Switchpack Mode
on page 5-4.
From the Main Menu, select option 3, Board Configuration.
Command
→
3
Board Configuration:
1)
HDSL Card Type
– CP
HDSL Interface/Rate – V.35 E1
2)
Loops Enabled
– Dual Loop (Loops A and B)
3)
Payload Rate
– 2048 Kbps (32x64)
4)
Transmit Timing
– loop
HDSL FW Rev
– 03
AT+T FW Rev
– 1.17
CP Serial #
– 85649
–––––––––––––––––––––––––––––––––––––––––––––
1–4) Board
Configuration
5) Switchpack
Definitions
?)
Prints Board Configuration and this menu
Q) Quit
Config
→