Customizing V.35/V.11-Compatible Units
5-6
7915-A2-GB20-20
September 1997
After you press a key to continue displaying the switchpack definitions, the
following table appears, providing information on how to set switches 3 through 7
in order to obtain your desired payload rate.
Switch pack S4 definition:
SWPK SWITCHES
| SWPK SWITCHES
RATE (Kbps) 7,6,5,4,3 | RATE (Kbps) 7,6,5,4,3
––––––––––––––––––––––––––––––––––––––––––––––––––––––
64 (1x64) 00000 | 1088 (17x64) 10000
128 (2x64) 00001 | 1152 (18x64) 10001
192 (3x64) 00010 | 1216 (19x64) 10010
256 (4x64) 00011 | 1280 (20x64) 10011
320 (5x64) 00100 | 1344 (21x64) 10100
384 (6x64) 00101 | 1408 (22x64) 10101
448 (7x64) 00110 | 1472 (23x64) 10110
512 (8x64) 00111 | 1536 (24x64) 10111
576 (9x64) 01000 | 1600 (25x64) 11000
640 (10x64) 01001 | 1664 (26x64) 11001
704 (11x64) 01010 | 1728 (27x64) 11010
768 (12x64) 01011 | 1792 (28x64) 11011
832 (13x64) 01100 | 1856 (29x64) 11100
896 (14x64) 01101 | 1920 (30x64) 11101
960 (15x64) 01110 | 1984 (31x64) 11110
1024 (16x64) 01111 | 2048 (32x64) 11111
Config
→
Examples:
— For 640 Kbps, set switch 7 OFF, 6 ON, 5 and 4 OFF, and 3 ON.
— For 1024 Kbps, set switch 7 OFF; switches 6, 5, 4, and 3 ON.
— For 2048 Kbps, set switches 7, 6, 5, 4, and 3 all to the ON position.
If you change from 2048 Kbps to a lower rate, and the far-end unit is
G.703-compatible, you must set the starting time slot on the G.703-compatible
unit and reset the units.