background image

 17

Declaration of Conformity

This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2
and 15 of the Federal Communications Commission’s Rules. This compliance
information statement pertains to the following products:

Trade Name:

Hotwire

Model Number:

5216-A3-200

This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may
cause undesired operation.

The name, address, and telephone number of the responsible party is given below:

Paradyne Corporation
8545 126th Avenue North
Largo, FL 33773-1502
Phone: (727) 530-2000

The authority to operate this equipment is conditioned by the requirement that no
modifications will be made to the equipment unless the changes or modifications are
expressly approved by Paradyne Corporation.

Japan

Notices

This is a Class B product based on the standard of the Voluntary Control Council for
Interference from Information Technology Equipment (VCCI). If this is used near a radio or
television receiver in a domestic environment, it may cause radio interference. Install and
use the equipment according to the instruction manual.

Содержание Hotwire 5216

Страница 1: ...cess over traditional twisted pair copper telephone wiring Copper pairs run from the central office CO to the customer premises CP to create the local loop The local loop terminates on the customer pr...

Страница 2: ...omer Premises CP DSL Ethernet Crossover Cable Central Office CO Demarcation Point Local Loop End user System DSL Digital Subscriber Line RTU Remote Termination Unit NID Network Interface Device New Wi...

Страница 3: ...ider DSL Access with a Hotwire 5038 Distributed POTS Splitter When a Hotwire 5038 Distributed POTS Splitter is used one 5038 Distributed POTS Splitter is installed as a phone filter for each telephone...

Страница 4: ...ckage Checklist Verify that your package contains the following Model 5216 Remote Termination Unit RTU DSL interface cable with RJ11 modular plugs Power cord with power transformer Wiring and Cables Y...

Страница 5: ...esidential locations Procedure 1 Access the punchdown block or NID 2 Disconnect the DSL access pair from the local loop WARNING Do not continue unless the DSL access line from the local loop has been...

Страница 6: ...n the following example a NID is used without a POTS splitter It includes an existing POTS line and a second pair installed for DSL access DSL POTS Access from Local Loop Wiring to DSL Jack Telephone...

Страница 7: ...7 15343 02 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring RTU Procedure 1 Wiring can be run from the punchdown bloc...

Страница 8: ...lled on the same line as POTS a Hotwire 5038 Distributed POTS Splitter can be used as a phone filter One 5038 Distributed POTS splitter is installed as a phone filter for each telephone on the POTS DS...

Страница 9: ...Interface Card Ethernet Line POWER ETHERNET DSL Hotwire RTU Ethernet Crossover Cable For RTU cable pin assignments refer to Cables Connectors on page 12 3 Insert the supplied power cord s round end in...

Страница 10: ...ing the power on self test After a successful self test the LEDs should appear as indicated in BOLD in the Condition column below LED Condition Status PWR ON The RTU has power ALM OFF ON No active ala...

Страница 11: ...minutes contact the service provider DSL LED is on and there is no data transmission The DSL link has been established but there is no data transmission Verify the Ethernet connection If the problem p...

Страница 12: ...2 Not used 3 DSL Ring 4 DSL Tip 5 6 Not used Ethernet interface crossover cable connector uses an 8 pin non keyed modular plug 10 100BaseT TX D 10 100BaseT TX D 10 100BaseT RX D Not Used Not Used 10...

Страница 13: ...nd 3 16 drill bit for the molly bolts Screwdriver A template with the dimensions for the three screws is provided See RTU Hardware Template on page 14 Procedure To mount the RTU 1 Use a drill to insta...

Страница 14: ...14 RTU Hardware Template Front LEDs 98 16171 5 43 7 55 To Bottom Hole...

Страница 15: ...SPR 22 Safety Certifications Class B Subpart B digital device Class B Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidi...

Страница 16: ...ction authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnec...

Страница 17: ...ause undesired operation The name address and telephone number of the responsible party is given below Paradyne Corporation 8545 126th Avenue North Largo FL 33773 1502 Phone 727 530 2000 The authority...

Страница 18: ...ctions United States Notice to Users of the Telephone Network 1 This equipment complies with Part 68 of the FCC rules On the equipment is a label that contains among other information the FCC registra...

Страница 19: ...commission or corporation commission for information 9 An FCC compliant telephone cord with modular plugs may be provided with this equipment This equipment is designed to be connected to the telephon...

Страница 20: ...butor locations or Paradyne worldwide office locations use one of the following methods H Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www p...

Отзывы: