Troubleshooting

LED Symptom

Action

All LEDs are on.

If the LEDs remain on for more than ten minutes, the RTU is
not functional. Unplug the unit and reapply power. If the ALM
LED is still on, contact the service provider.

ALM LED remains
on.

The power-on self-test may have failed. Unplug the unit and
reapply power. If the alarm light is still on, contact the service
provider.

ALM and TST
LEDs are blinking.

Firmware download may be in progress. If firmware download
is not in progress or the LEDs continue blinking for more than
ten minutes, contact the service provider. Do not unplug the
unit, unless instructed to do so by the service provider.

DSL LED is off.

Verify that the DSL cable is securely installed on both ends. 
Unplug the unit and reapply power. If the problem continues,
contact the service provider.

DSL LED continues
to blink after the
power-on self-test.

The RTU is attempting to establish the DSL link or adjusting
the rate of the DSL line due to line conditions. If the DSL LED
continues to blink for more than ten minutes, contact the
service provider.

DSL LED is on and
there is no data
transmission.

The DSL link has been established but there is no data
transmission. Verify the Ethernet connection. If the problem
persists, contact the service provider.

DSL and Ethernet
LEDs are on and
there is no data
transmission.

The DSL and the Ethernet links have been established but
there is no data transmission. If the problem continues, contact
the service provider.

Ethernet LED is off.

Verify that the Ethernet cable is securely installed at both ends,
and that at least one PC is connected and powered on.

Verify that the correct crossover cable is installed. Refer to
Installing the Hotwire 5216 RTU on page 8.

PWR LED is off.

Check that the power cord is securely installed on both ends.

If no LEDs are on, the power supply may be defective. Test the
outlet to verify power. If the problem persists, contact the
service provider.

If other LEDs are on, the PWR light may be burned out. Unplug
the unit and reapply power; watch all LEDs during the
power-on self-test to verify that the PWR LED is functioning.

TST LED is on.

A test initiated by the service provider may be active. Wait ten
minutes. If the TST LED does not go off, contact the service
provider.

Содержание Hotwire 5216

Страница 1: ...cess over traditional twisted pair copper telephone wiring Copper pairs run from the central office CO to the customer premises CP to create the local loop The local loop terminates on the customer pr...

Страница 2: ...omer Premises CP DSL Ethernet Crossover Cable Central Office CO Demarcation Point Local Loop End user System DSL Digital Subscriber Line RTU Remote Termination Unit NID Network Interface Device New Wi...

Страница 3: ...ider DSL Access with a Hotwire 5038 Distributed POTS Splitter When a Hotwire 5038 Distributed POTS Splitter is used one 5038 Distributed POTS Splitter is installed as a phone filter for each telephone...

Страница 4: ...ckage Checklist Verify that your package contains the following Model 5216 Remote Termination Unit RTU DSL interface cable with RJ11 modular plugs Power cord with power transformer Wiring and Cables Y...

Страница 5: ...esidential locations Procedure 1 Access the punchdown block or NID 2 Disconnect the DSL access pair from the local loop WARNING Do not continue unless the DSL access line from the local loop has been...

Страница 6: ...n the following example a NID is used without a POTS splitter It includes an existing POTS line and a second pair installed for DSL access DSL POTS Access from Local Loop Wiring to DSL Jack Telephone...

Страница 7: ...7 15343 02 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring RTU Procedure 1 Wiring can be run from the punchdown bloc...

Страница 8: ...lled on the same line as POTS a Hotwire 5038 Distributed POTS Splitter can be used as a phone filter One 5038 Distributed POTS splitter is installed as a phone filter for each telephone on the POTS DS...

Страница 9: ...Interface Card Ethernet Line POWER ETHERNET DSL Hotwire RTU Ethernet Crossover Cable For RTU cable pin assignments refer to Cables Connectors on page 12 3 Insert the supplied power cord s round end in...

Страница 10: ...ing the power on self test After a successful self test the LEDs should appear as indicated in BOLD in the Condition column below LED Condition Status PWR ON The RTU has power ALM OFF ON No active ala...

Страница 11: ...minutes contact the service provider DSL LED is on and there is no data transmission The DSL link has been established but there is no data transmission Verify the Ethernet connection If the problem p...

Страница 12: ...2 Not used 3 DSL Ring 4 DSL Tip 5 6 Not used Ethernet interface crossover cable connector uses an 8 pin non keyed modular plug 10 100BaseT TX D 10 100BaseT TX D 10 100BaseT RX D Not Used Not Used 10...

Страница 13: ...nd 3 16 drill bit for the molly bolts Screwdriver A template with the dimensions for the three screws is provided See RTU Hardware Template on page 14 Procedure To mount the RTU 1 Use a drill to insta...

Страница 14: ...14 RTU Hardware Template Front LEDs 98 16171 5 43 7 55 To Bottom Hole...

Страница 15: ...SPR 22 Safety Certifications Class B Subpart B digital device Class B Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidi...

Страница 16: ...ction authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnec...

Страница 17: ...ause undesired operation The name address and telephone number of the responsible party is given below Paradyne Corporation 8545 126th Avenue North Largo FL 33773 1502 Phone 727 530 2000 The authority...

Страница 18: ...ctions United States Notice to Users of the Telephone Network 1 This equipment complies with Part 68 of the FCC rules On the equipment is a label that contains among other information the FCC registra...

Страница 19: ...commission or corporation commission for information 9 An FCC compliant telephone cord with modular plugs may be provided with this equipment This equipment is designed to be connected to the telephon...

Страница 20: ...butor locations or Paradyne worldwide office locations use one of the following methods H Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www p...

Отзывы: