8
Installing and Setting Up the FrameSaver SLV
To complete the installation, you must:
Configure the FrameSaver unit.
Connect to the network.
Configure SNMP Trap Managers.
Connect to the DSX, if applicable (T1 units only).
Connect to the DTE equipment.
NOTE:
Follow these instructions as they are presented. Installation time will be increased
if you connect the cables first.
Verifying that Self-Test Passed
Before starting to configure the FrameSaver unit, confirm that the unit passed the
self-test.
1. Follow this menu selection sequence from the Main Menu, pressing Enter after
each selection:
Main Menu
→
Status
→
System and Test Status
2. Check the Self-Test Results column (in the center of the System and Test Status
screen).
– If Passed appears, the FrameSaver unit successfully completed the self-test.
– If any failure messages appear, reset the unit by disconnecting, then reconnecting
the power cord. The unit will perform the Self-Test again. If the failure reappears,
call your service representative for assistance. You may need to return the unit to
the factory.
Configuring the FrameSaver Unit
To configure the FrameSaver unit:
Enter time slot assignments, if installing a FrameSaver 9124.
Set up for management.
Set up Auto-Configuration.