11
It is assumed that frame relay service is turned on at the site.
Procedure
1.
Select the Easy Install feature.
Main Menu
→
Easy Install
2.
Enter the Node IP Address and Subnet Mask.
3.
Set TS Access to DLCI, then select a DLCI on the network interface that will be
used for the troubleshooting access link.
4.
Create a Dedicated Network Management Link, selecting a DLCI for the
management link at the
Which DLCI would you like to Create a
Dedicated Network Management Link on?
prompt, which will be used by
the NOC to access the unit.
5.
Configure the T1 network interface options to match the service provider’s settings.
6.
Save the configurations.
7.
Install the network cable (see
Connecting to the Network
on page 22). The
FrameSaver unit starts discovering DLCIs and network time slots (see
Automatic
Configuration
on page 15).
The remaining steps are optional, depending upon the application. They are performed
from the Main Menu.
8.
If the unit will be enforcing CIR (Committed Information Rate) and EIR (Excess
Information Rate) on network frame relay links, enable Traffic Policing.
Main Menu
→
Configuration
→
Network
→
Frame Relay
You can change other Frame Relay and LMI default settings, if necessary.
9.
Configure each interface according to the local management interface (LMI) and
assigned line conditions supplied by the service provider.
Configuration
→
Network
→
Frame Relay
Configuration
→
Data Ports
→
Frame Relay
10.
Set up SNMP local management (see
Setting Up Local Management at the Central
Site
on page 15).
11.
Set up the modem, and the Call Directories if trap dial-out is desired (see
Setting
Up the Modem
on page 16).
12.
If the unit has ISDN backup capability, set up the DBM (see
Setting Up the ISDN
DBM
on page 18).
13.
If SNMP traps are wanted, set up managers, select the desired traps, and configure
trap dial-out if desired (see
Configuring SNMP Trap Managers and Trap Dial-Out
on
page 21).
14.
Save the configurations.
15.
Verify the entire path from the remote unit to the NMS is functioning (see
Verifying
the End-to-End Path
on page 23).