Configuration
8-26
9124-A2-GH30-00
June 1999 - Preliminary
Table 8-2.
Service Level Verification Options (2 of 2)
SLV Timeout Error Event Threshold
Available Settings: 1, 2, 3, 4 . . . 20
Default Setting: 3
Specifies the number of consecutive SLV commnications that must be received before
an SLV Timeout Error Event is declared.
1– 20 – Sets the limit for these error events.
SLV Timeout Clearing Event Threshold
Available Settings: 1, 2, 3, 4 . . . 20
Default Setting: 1
Specifies the number of consecutively missed SLV communications that willl be
received before the SLV Timeout Error Event is cleared.
1– 20 – Sets the limit for the clearing event.
Configuring General System Options
Select General to display or change the general system configuration options
(see Table 8-3). Follow this menu selection sequence:
Main Menu
→
Configuration
→
System
→
General
Table 8-3.
General System Options (1 of 2)
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether or not loopback and pattern tests have a duration after which they
are terminated automatically.
Enable – All Loopback and Pattern tests have a timeout. This setting is recommended
when the FrameSaver unit is managed remotely through an in-band data stream. If the
FrameSaver unit is accidently commanded to execute a disruptive test on the interface
providing the management access, control can be regained after the timeout expires,
terminating the test.
Disable – Loopback and pattern tests must be manually terminated.
Test Duration (min)
Possible Settings: 1 – 120
Default Setting: 10
Specifies the maximum duration of the tests.
Display Conditions – This option only appears when Test Timeout is set to Enable.
1 – 120 – Sets the Test Timeout period in minutes (inclusive).
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...