5 Diagnostics
980-001-0221C
FrameSaver NP 64+ User’s Manual - Installation Guide
5-13
March 2001
RxPkts & TxPkts - Count of packets received (Rx) and count of packets sent (Tx).
NOTE: Measurement Packets (Delay, Loss, & Link Test) are included in the
RxPkts and TxPkts counts of the FrameSaver NP originating the packets.
Measurement packets are included only in the RxPkts count of a FrameSaver NP
looping (receiving and returning) Measurement Packets.
BECN & FECN - Count of packets with the BECN or FECN bit set. If the count ex-
ceeds 9999, the displayed value will be 9999.
RxDE & TxDE - Count of packets received (Rx) with the DE bit set and count of pack-
ets sent (Tx) with the DE bit set (does not include Measurement Packets).
Delay (mS) Avg & Max - Average and Maximum round trip delay of Delay measure-
ment Packets echoed by a distant FrameSaver NP unit. These values are overwrit-
ten with 9999 during an interval where PVC “Drpd Mon Pkt Alarm” has been
detected for that specific PVC. These values are set to “0” (zero) for PVCs not des-
ignated for the sending of Delay Packets.
NOTE: Sending of Delay and Loss measurement packets is suspended for ALL
PVCs while a “Test Pkts to Netw” (operator initiated) test is performed on any
PVC.
As PVCs are passed, new DLCIs are added to the list which are displayed in numerical
DLCI order. If the total number of DLCIs with traffic exceeds nine, within the interval,
the tenth line labeled “Etc” appears containing the count of all packets not counted in
the previous nine.
n Minute Interval History - Displays the number of valid intervals that have been ac-
cumulated since the last reset of the counters. (“n” value is Interval Period set on the
PVC Performance Configuration screen.) History statistics are total counts for each
performance parameter over all valid intervals up to 96 intervals.
Past Summary for DLCI [D=#orSum] - Determines what part of statistics history
will be used to produce the 10-second and History statistics displays. Choices
are:
Specific PVC - Enter DLCI number (#) or “Etc,” for that PVC.
Sum of all PVCs - Enter Sum (or only “S”).
Frame Relay traffic parameters displayed are the same as for Current Interval above.
10 Secs: - Counts for each of the performance parameters for the selected PVC(s) ac-
cumulated during the first 10-second period after entering this screen.
NOTE: This count will update every 10 seconds only if AutoUpdate [AU] is activated.
History: - Total counts for each of the performance parameters for the selected PVC(s)
over all valid intervals up to a maximum of 96 intervals. Does not include current in-
terval.
Содержание FrameSaver NP 64+
Страница 2: ......
Страница 8: ...Table of Contents iv FrameSaver NP 64 User s Manual Installation Guide 980 001 0221C March 2001...
Страница 19: ...1 Preface 1 7 FrameSaver NP 64 User s Manual Installation Guide 980 001 0221C March 2001...
Страница 35: ...2 Description 2 16 FrameSaver NP 64 User s Manual Installation Guide 980 001 0221C March 2001...
Страница 115: ...6 2 FrameSaver NP 64 User s Manual Installation Guide 980 001 0221C March 2001 This page intentionally left blank...