3 Installation
980-001-0221C
FrameSaver NP 64+ User’s Manual - Installation Guide
3-19
March 2001
Power Control Unit
Specifications
Table 3-13 Model 467 Power Control Unit General Specifications
Item
Description
Dimensions
2.5" H x 7.25" W x 4.6"D
Weight
As packaged including carton: 4.5 lbs.
Unit alone: 3.5 lbs.
Operating Range
Temperature: 0 to 50 degrees C. operating.
Relative Humidity: 5 to 95% non-condensing.
Altitude: 10,000 ft. max. operating,
50,000 ft. max. non-operating.
Shock and Vibration: As normally encountered during shipping and handling.
Power Requirements
AC Input: 125 VAC, 50 - 60 Hz, 0.22A for the internal power transformer in
addition to the connected device.
7-foot cord with 3-prong connectors.
Switched AC Output: 125 VAC, 5 AMPS max.
7-foot cord with 3-prong connectors.
Power Output: 22 VAC, 30 VA (FrameSaver NP 64+ Only).
7-foot Control/Power Cable: 4-conductor with 4-pin keyed locking connectors.
Regulatory Compliance
UL - 1950