Making DROP/DSX Option Connections (FrameSaver NP 110 only)
FrameSaver NP 110 units equipped with optional DROP/DSX adapters have addition-
al connectors on the rear panel for the DROP and DSX Ports. The DROP Port supports
the ITU-V.35 interface and the DSX Port is aT1 Network interface.
FrameSaver NP 64+ Specifications
Power Up a FrameSaver NP 110
Power Connections
1. Plug the IEC 320 end of the Power Cord into the connector on the rear of the
FrameSaver NP 120.
2. Plug the other end of the Power
Cord into an AC outlet.
3. The unit will go through the following power-up sequence
FrameSaver NP 110 Power-Up Sequence
If the LED indications are not as described above, refer to Section 5, “Diagnostics” of
the FrameSaver NP 110 User’s Manual - Installation Guide. If operation looks nor-
mal, unplug the FrameSaver NP before making input/output connections.
If the unit is to supply switched power to another device, plug that device’s power cord
into the Switched AC Out connector now.
Proceed to Making Network and Input/Output Connections on page 9 of this guide.
Item
Description
Dimensions
Table Top (with rubber feet):
3.0" H x 8.5" W x 11.5" D.
Wall Mount (with removable wall mounting bracket):
8.5" H x 11.5" W x 3.0" D.
Rack Mount (with removable rack mounting adapter):
3.5" H x 19.0" W ( or 24.0" W ) x 11.5" D.
Weight
As normally packaged including carton and accessories: 6 lbs.
Unit alone (without packaging and accessories): 4 lbs.
Operating
Range
Temperature: 0 to 50 degrees C. operating.
Relative Humidity: 5 to 95% non-condensing.
Altitude: 10,000 ft. max. operating,
50,000 ft. max. non-operating.
Shock and Vibration: As normally encountered during
shipping and handling.
Power
Requirements
AC Power Pack (transformer/plug module).
Input = 90 - 130 VAC, 0.2 A max., 60 Hz.
Output = 22 VAC, 30 VA.
Cable: 2-conductor, with 2-pin keyed locking connector,
7 ft. length.
Regulatory
Compliance
UL - 1459, Third Edition and CAN/CSA C22.2 No. 225-M90
FCC Part 15, Class A Digital Device
Canada’s ICES003, Class A Digital Device
FCC Part 68
Basic FrameSaver NP 110
FrameSaver NP 110 with ISDN
UNIT POWER LED lights and stays on.
UNIT READY LED flashes during
self-test (approximately 60 seconds).
UNIT READY and ISDN READY
LEDs flash during self-test
(approximately 60 seconds).
UNIT READY LED is ON steady after
completion of self-test.
UNIT READY and ISDN READY
LEDs are ON steady after completion
of self-test.
NETW ALARM and UNIT FRM MGMT LEDs should not be flashing together.
All other LED indications should be ignored at this time.
U S E R P O R T
FU S E
5 A/2 5 0 V
S LO W B L O W
5 x2 0 m m
1 00 -24 0 V A C
5 A
5 0-6 0 H z
O
N
1 2
FO R C O N T IN U E D
P R O TE C TIO N
A G A IN S T R IS K
O F FIR E ,
R E P L A C E O N LY
W ITH S AM E TY P E
A N D R A TIN G
O F FU S E .
"C AU TIO N "
S W ITC H E D
A C O U T
2 50 V A C
4 .5A M A X
1 2
7
10
AC Power Connector
IEC 320 (male)