4. Configuration Options
9700-A2-GB20-20
December 2002
4-45
Primary Link RIP
Possible Settings:
None, Proprietary, Proprietary In, Standard_out
Default Setting:
–
For multiplexed DLCIs:
Proprietary
–
For nonmultiplexed DLCIs:
Standard_out
Specifies which Routing Information Protocol (RIP) is used to enable routing of
management between FrameSaver units and attached equipment.
Display Conditions – This option does not appear if Payload Managed is enabled.
None
– Does not use a routing protocol.
Proprietary
– Uses a proprietary variant of RIP Version1 to communicate routing
information between FrameSaver units. A FrameSaver unit must be on the other end of
the link. This is the factory default for management PVCs configured on multiplexed DLCIs
(see
Table 4-11, Circuit Records Options
).
Proprietary In
– (Release 2.1.) The device distributes only the following local routes to
the far end:
– Trap manager routes
– Default route
– Routes to this device
– MIB-injected routes
– RIP split horizon with poison reversed routes
Standard_out
– The device sends standard RIP messages to communicate routing
information only about FrameSaver units in the network. This is the factory default for
management PVCs configured on standard DLCIs.
NOTE: The router must be configured to receive RIP on the FrameSaver management
interface port.
Encapsulation
Possible Settings:
Routed
Default Setting:
Routed
This read-only field specifies that the IP encapsulation used is RFC 1490/RFC 2427
routed Network Level Protocol IDentifier (NLPID) encapsulation, and not SubNetwork
Access Protocol (SNAP) encapsulation.
Display Conditions – This option appears only if the PVC is Payload Managed or IP
Enabled.
Routed
– IP encapsulation is routed NLPID.
Table 4-19. Management PVC Options (4 of 4)
Содержание FrameSaver 9720
Страница 1: ...FrameSaver DSL Models 9720 9783 and 9788 User s Guide Document No 9700 A2 GB20 20 December 2002...
Страница 24: ...1 About FrameSaver DSL Devices 1 10 December 2002 9700 A2 GB20 20...
Страница 34: ...2 User and Command Line Interfaces and Basic Operation 2 10 December 2002 9700 A2 GB20 20...
Страница 104: ...4 Configuration Options 4 64 December 2002 9700 A2 GB20 20...
Страница 224: ...9 Setting Up OpenLane for FrameSaver Device 9 10 December 2002 9700 A2 GB20 20...
Страница 240: ...A Menu Hierarchy A 6 December 2002 9700 A2 GB20 20...
Страница 318: ...E Connectors Cables and Pin Assignments E 14 December 2002 9700 A2 GB20 20...
Страница 326: ...G Equipment List G 6 December 2002 9700 A2 GB20 20...