 12

Access Unit LEDs

Label

Indication

Color

What It Means

OK

Power and
Operational
Status

Green

ON –

Access unit has power and is 
operational.

OFF –

Access unit is in a power-up 
self-test, or there is a failure.

Blinking ON and OFF ( Rate: 1 Hz ) –

Software is being downloaded.

ALM

Operational
Alarm ( Fail )

Red

ON –

Access unit has just been reset, or 
an error or fault has been detected.

OFF –

No failures have been detected.

TST

Test Mode

Yellow

ON –

Loopback or test pattern in 
progress, initiated locally, remotely, 
or from the network.

OFF –

No tests are active.

BKP

1

Backup

Yellow

ON –

Access unit is in Backup mode; that
is, the backup link has been 
established, and backup is in 
progress through the specified 
Alternate Destination Link.

OFF –

Access unit is not in Backup mode.

Blinking ON and OFF ( Rate: 1 Hz ) –

Alternate Destination Link is being 
established, but no data has been 
passed.

1

The BKP LED indicates backup for an ISDN BRI DBM or external backup device.

Содержание FrameSaver 9620

Страница 1: ...ns Document No 9000 A2 GN1D for power up verification procedures if using an access carrier ISDN BRI Dial Backup Module DBM Installation Instructions Document No 9000 A2 GN19 to uninstall then reinsta...

Страница 2: ...1 Slot Housing Before replacing a NAM locate or record the access unit s configuration options or transfer the configuration using the FTP file transfer protocol feature This is useful when setting u...

Страница 3: ...very carefully and gently pulling and rocking the NAM connectors away from the I O card connectors Work first from one side then the other until the NAM is separated from the I O card Set the NAM asid...

Страница 4: ...ns 4 Place the NAM and integrated I O card backplane into the 1 slot housing s base Make sure the backplane rests inside the guides on the base at the rear of the access unit 5 Place the cover over th...

Страница 5: ...s I O card provides the COM port network and DTE connections The I O card inserts directly behind the NAM that it supports 1 Remove the I O card from the shipping box Handle only by the top and bottom...

Страница 6: ...the NET interface 2 Insert the other end of the cable into the RJ48S modular jack Connecting to a DTE If the DTE cable type is V 35 1 Connect the plug to the V 35 end of the adapter cable 2 Connect th...

Страница 7: ...w Control set to None 2 Insert the 8 pin end of the cable into the COM port 3 Insert the other end of the cable into the user interface VT100 compatible terminal emulation connector PORT 2 COM COM 98...

Страница 8: ...and bottom edges to avoid damaging the card 2 At the front of the carrier align the NAM with the upper and lower tracks of the appropriate slot 97 15754 Ejector Latches Front View 3 Slide the NAM into...

Страница 9: ...Close both the upper and lower ejector latches on the carrier to lock in place then tighten the captive screws Removing Replacing the I O Card 1 Remove the NAM from the carrier see Removing Replacing...

Страница 10: ...receptacle power by plugging in some equipment that is known to be working 2 Check the circuit breaker LED is burned out Run the Lamp Test If the LED in question does not flash with the other LEDs the...

Страница 11: ...O K A L M T S T B K P D M O O S O O F N S P 1 P 2 T X D R X D D T R 9621 496 14957 Faceplate for 1 Slot Housing The access unit s faceplate includes 12 LEDs light emitting diodes that provide status...

Страница 12: ...ted OFF No failures have been detected TST Test Mode Yellow ON Loopback or test pattern in progress initiated locally remotely or from the network OFF No tests are active BKP1 Backup Yellow ON Access...

Страница 13: ...s not in service and the access unit is receiving an out of service indicator OFF Access unit is not receiving an out of service indicator OOF NS Out of Frame No Signal Red ON No signal is being recei...

Страница 14: ...e humidity Shock and vibration 35 F to 122 F 1 7 C to 50 C 4 F to 158 F 20 C to 70 C Up to 90 noncondensing Withstands normal shipping and handling Approvals FCC Part 15 FCC Part 68 Industry Canada UL...

Страница 15: ...ived Clock RXC From DCE Out 8 EIA 232E DTE Ports Interfaces Signal Circuit Mnemonic ITU CCITT Direction 25 Pin EIA 232E Pin Shield 1 Transmitted Data TXD BA 103 To DCE 2 Received Data RXD BB 104 From...

Страница 16: ...nt Timing TXC DB 114 From DCE 15 Reserved for future use 16 Receiver Signal Element Timing RXC DD 115 From DCE 17 Local Loopback LL LL 141 To DCE 18 Not used 19 Data Terminal or DTE Ready DTR CD 108 1...

Страница 17: ...to the network T 2 Receive tip from the network T1 7 Receive ring from the network R1 8 BKP Port Interface 1 Slot Housing Only Function Circuit Pin Transmit Receive ring to from the local loop R R1 4...

Отзывы: