Paradyne COMSPHERE 3821PLUS Скачать руководство пользователя страница 2

Copyright 

 1998 Paradyne Corporation.

All rights reserved.
Printed in U.S.A.

Notice

This publication is protected by federal copyright law. No part of this publication may be
copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated
into any human or computer language in any form or by any means, electronic,
mechanical, magnetic, manual or otherwise, or disclosed to third parties without the
express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, 
FL  33773.

Paradyne Corporation makes no representation or warranties with respect to the
contents hereof and specifically disclaims any implied warranties of merchantability or
fitness for a particular purpose. Further, Paradyne Corporation reserves the right to
revise this publication and to make changes from time to time in the contents hereof
without obligation of Paradyne Corporation to notify any person of such revision or
changes.

Changes and enhancements to the product and to the information herein will be
documented and issued as a new release to this manual.

Warranty, Sales, and Service Information

Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:

Via the Internet:  Visit the Paradyne World Wide Web site at 
http://www.paradyne.com

Via Telephone:  Call our automated call system to receive current information via
 fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340

Trademarks

All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.

Document Feedback

We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.

Содержание COMSPHERE 3821PLUS

Страница 1: ...COMSPHERE 3821Plus MODEM QUICK REFERENCE Document No 3821 A2 GL10 00...

Страница 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Страница 3: ...PHERE 3821Plus Modem User s Guide To request a paper copy of a Paradyne document Within the U S A call 1 800 PARADYNE 1 800 727 2396 Outside the U S A call 1 727 530 8623 3821Plus Installation A typic...

Страница 4: ...nd its power supply can be found in the COMSPHERE 3000 Series Carrier Installation Manual Document Number 3000 A2 GA31 Install the NIM A NIM can be installed on the left or right side of the back of t...

Страница 5: ...the 50 pin connector in the middle of the NIM Connect the other end to the dial or leased line interface This may be an RJ11 gang box or a 66A punchdown block 495 14798 NETWORK INTERFACE CABLE P21 or...

Страница 6: ...ce assembly it must be mounted on the same side you installed the NIM Procedure 1 Feed the eight tabs at the bottom of the DTE interface assembly into the slots on the left or right side of the carrie...

Страница 7: ...til the back edge of the card seats in the socket of the DTE interface assembly 495 14797 Procedure 1 Turn the circuit pack lock until it is vertical locking the 3821Plus card in place 2 When all card...

Страница 8: ...instructions to the modem A dumb asynchronous terminal however does not require this software since it can directly send AT commands The 3821Plus can be used with any major communications software Re...

Страница 9: ...inate mode 5 Press the key until the appropriate factory preset appears on the LCD and press the corresponding function key to select your choice 6 Choose Function appears and displays the Edit and Sa...

Страница 10: ...may have lost AT command control To regain AT command control select via the SDCP the Async Dial factory preset configuration To change a factory template using AT commands perform the following step...

Страница 11: ...st connected to a 3821Plus card using the Select key on the SDCP F1 Idle 33 6 MDMA mdmb mdmc F2 F3 Press F1 F2 or F3 to connect the SDCP to modem A B or C respectively The connected modem appears on t...

Страница 12: ...Modem Status MDMA mdmb mdmc Call_Setup Status Branch The Status branch of the Top Level menu allows you to view the current status of the dial or leased line connection the DTE interface and the ident...

Страница 13: ...ommunication problems such as periodic character loss random errors or constant format errors By the process of elimination you can usually isolate the fault in your system Abort Self Loc_Analog_Loop...

Страница 14: ...Operating Active Saved Customer1 Customer2 Factory Async_Dial Sync_Dial Sync_Leased UNIX_Dial Choose Mode Answer Originate Ld EditArea frm Edit Save Choose Function Active Saved Customer1 Customer2 DT...

Страница 15: ...ervLine Download Code 495 14846 Call_Setup Test Security Configure Remote Status Modem Status MDMA mdmb mdmc Control Remote Branch The Remote Access feature of 3821Plus modems allows you to change con...

Страница 16: ...Control and Reset Security 495 14847 Set_Access_Ctrl Admin Password Reset_Security EditPassWdTable Set_Answer_Sec Set_Admin_PsWd Set_Orig_Secur Set_CallBack_Sec Security Call_Setup Control Test Config...

Страница 17: ...o Result Codes section Q1 Disables result codes Q2 Enables originate modem to send result codes to the DTE Required for most UNIX applications Sn Displays value of S Register where n is the register n...

Страница 18: ...ar PSTN if ETC installed Gn V 22bis Guard Tone G0 Disables guard tone G1 Sets guard tone to 550 Hz G2 Sets guard tone to 1800 Hz AT COMMANDS continued In Dial Transmit Level I10 10 dBm I11 11 dBm I32...

Страница 19: ...er An Maximum Frame Size A0 64 A1 128 A2 192 A3 256 A4 32 A5 16 AT COMMANDS continued Cn Error Control Negotiate Buffer C0 Data is not buffered during handshaking sequence C1 Data is buffered up to 4...

Страница 20: ...sthrough X1 Enables XON XOFF Passthrough An Sets error control fallback character n to an ASCII value from 0 to 127 Bn Sets modulation to V 34 and VF rate to n 300 1200 or 2400 to 33600 in increments...

Страница 21: ...32bis 4 7200 V 32bis 5 4800 V 32bis 6 2400 V 22bis 7 1200 V 22 8 1200 212A 10 0 300 V 21 11 0 300 103J 20 19200 V 32terbo 21 16800 V 32terbo 27 33600 V 34 28 31200 V 34 29 28800 V 34 30 26400 V 34 31...

Страница 22: ...anagement Address 255 0 255 001 256 S76 Dial Autorate 0 0 Enable 1 Disable 2 Start at 4800 3 Start at 9600 S77 DTR Alarm Reporting 0 0 Disable 1 Enable S78 Dial Automode 0 0 Enable 1 Disable 2 System8...

Страница 23: ...the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a voltage potential be...

Страница 24: ...uipment designed for use within certain voltage limits as amended by Directive 93 68 EEC Directive 89 336 EEC Council Directive of 3 May 1989 on the approximation of the laws of the Member States rela...

Страница 25: ...ustomer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 5 The telephone company may make changes in its facilities equipment...

Страница 26: ...an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone exte...

Страница 27: ...tus shall comprise only i apparatus approved for the purpose of connection between the apparatus and a speechband circuit and ii cable or wiring complying with a code of practice for the installation...

Страница 28: ...g to the instruction manual Restrictions Due to JATE Japan Approvals Institute for Telecommunications Equipment regulations only 3 attempts to dial a number are permitted in a 3 minute period If a fou...

Отзывы: