background image

Safety Instructions

B

3610-A2-GB43-50

December 1996

Important Safety Instructions

1.

Read and follow all warning notices and instructions marked on the product or included in the
manual.

2.

This product is intended to be used with a three-wire grounding type plug – a plug which has
a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe
operation. Do not defeat the purpose of the grounding type plug by modifying the plug or
using an adapter.

Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the
presence of earth ground. If the receptacle is not properly grounded, the installation must not
continue until a qualified electrician has corrected the problem.

If a three-wire grounding type power source is not available, consult a qualified electrician to
determine another method of grounding the equipment.

3.

Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of
the product and to protect it from overheating, these slots and openings must not be blocked
or covered.

4.

Do not allow anything to rest on the power cord and do not locate the product where persons
will walk on the power cord.

5.

Do not attempt to service this product yourself, as opening or removing covers may expose
you to dangerous high voltage points or other risks. Refer all servicing to qualified service
personnel.

6.

General purpose cables are provided with this product. Special cables, which may be required
by the regulatory inspection authority for the installation site, are the responsibility of the
customer.

7.

When installed in the final configuration, the product must comply with the applicable Safety
Standards and regulatory requirements of the country in which it is installed. If necessary,
consult with the appropriate regulatory agencies and inspection authorities to ensure
compliance.

8.

A rare phenomenon can create a voltage potential between the earth grounds of two or more
buildings. If products installed in separate buildings are interconnected, the voltage potential
may cause a hazardous condition. Consult a qualified electrical consultant to determine
whether or not this phenomenon exists and, if necessary, implement corrective action prior to
interconnecting the products.

In addition, if the equipment is to be used with telecommunications circuits, take the following
precautions:

Never install telephone wiring during a lightning storm.

Never install telephone jacks in wet locations unless the jack is specifically designed for wet 
locations.

Never touch uninsulated telephone wires or terminals unless the telephone line has been 
disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Avoid using a telephone (other than a cordless type) during an electrical storm. 
There may be a remote risk of electric shock from lightning.

Do not use the telephone to report a gas leak in the vicinity of the leak.

Содержание COMSPHERE 3610

Страница 1: ...COMSPHERE 3600 SERIES DATA SERVICE UNITS MODELS 3610 AND 3611 DOCUMENTATION REPLACEMENT Document No 3610 A2 GB43 50 Feature No 3600 G3 002 December 1996...

Страница 2: ...ne com Via Telephone Call our automated call system to receive current information via fax or to speak with a company representative Within the U S A call 1 800 870 2221 International call 727 530 234...

Страница 3: ...fied service personnel 6 General purpose cables are provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibil...

Страница 4: ...COMSPHERE 3600 Series Data Service Units C December 1996 3610 A2 GB43 50 Notices...

Страница 5: ...5 Call your local telephone company to ascertain the maximum REN for your calling area If your Model 3610 or 3611 DSU with DBM causes harm to the telephone network the telephone company may discontin...

Страница 6: ...lation Requirements DBM Type USOC Jack Standalone USOC Jack Carrier Mounted Canadian Jack Standalone Canadian Jack Carrier Mounted 12 0 or 14 4 kbps V 32bis DBM RJ11C Permissive RJ45C Programmable RJ2...

Страница 7: ...telephone lines and internal metallic water pipe system if present are connected together for protection This precaution may be particularly important in rural areas CAUTION Users should not attempt...

Страница 8: ...Modules DBMs Time Division Multiplexer TDM Multichannel Multipoint MCMP and the digital bridge options Chapter 2 describes electrical connection of the Model 3610 DSU as well as Digital Data Service D...

Страница 9: ...Manual 3610 A2 GH30 Orderable Provides detailed information on the DSU DBM SNA Diagnostic Interface TDM MCMP and Digital Bridge features specifications configuration scenarios async terminal operatio...

Страница 10: ...ble 1 1 1 of 3 General COMSPHERE 3600 Series Technical Specifications Specifications Criteria AC POWER FUSE Model 3610 3611 DSU 3000 Series Carrier No accessible fuse 4 amp fuse Paradyne part number 1...

Страница 11: ...CCITT V 24 ISO 2110 ITU CCITT V 35 ISO 2593 A modular DSU V 35 interconnect cable is required to use the V 35 connector The cable provides an interface between the DSU s 25 pin D type connector and t...

Страница 12: ...NS 3610 DSU Height Width Depth 3611 DSU non modular or modular Height Width thickness Depth Rear Connector Plate 2 port Height Width Depth 25 Pin V 35 Interface 3000 Series Carrier Height Width Depth...

Страница 13: ...610 DSU 3611 DSU Requires 3600 Hubbing Device which provides two 8 pin modular jacks Via the SDU in the COMSPHERE 3000 Series Carrier or DC OUT via NMS adapter cable for a tributary in the carrier NET...

Страница 14: ...ICATION Diagnostic interfaces for the Model 3610 DSU NETWORK MANAGEMENT INTERFACES NMS Two 8 pin modular jacks Note that the 3600 Hubbing Device has a 6 inch attached cable that terminates in a 4 pin...

Страница 15: ...4 8 7 2 9 6 12 14 4 kbps DBM COMPATIBILITY If Call Setup is set for Callback or Password security then the device is compatible with a 3600 Series V 32 DBM only If Call Setup is set for Alarm or None...

Страница 16: ...ter Receiver Compromise equalizer Automatic adaptive equalizer COMMUNICATION LINE 2 wire analog PSTN line DATA RATES 2 4 4 8 7 2 9 6 12 14 4 16 8 19 2 21 6 24 26 4 and 28 8 kbps DBM COMPATIBILITY If C...

Страница 17: ...COMMUNICATION LINE A dedicated 2 wire access or a local exchange carrier 2 wire switched access DATA RATES 56 kbps Note that 2 wire Switched 56 DBM or DBM D use proprietary rate adaption to support da...

Страница 18: ...local exchange carrier 4 wire switched access DATA RATES 56 kbps Note that 4 wire Switched 56 DBM or DBM S use proprietary rate adaption to support data rates of less than 56 kbps DBM COMPATIBILITY If...

Страница 19: ...equalizer with echo cancellation COMMUNICATION LINE 2 wire BRI ISDN line DATA RATES 56 and 64 kbps Note that ISDN DBM or DBM I use proprietary rate adaption to support data rates of less than 64 kbps...

Страница 20: ...onnector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater Provides five additional 25 pin D subminiature con...

Страница 21: ...additional 25 pin D subminiature connector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater Provides five a...

Страница 22: ...independently of each other when you have DSU firmware Release 6 28 or greater Provides five additional 25 pin D subminiature connectors for a total of six EIA 232 or V 35 interfaces that can be set...

Страница 23: ...within 6 feet that is protected by a circuit breaker Label the circuit breaker that protects the ac outlet and ensure that the circuit breaker is set to ON Your installation site is clean well lit ven...

Страница 24: ...or by using an adapter Prior to installation use an outlet tester or voltmeter to check the ac receptacle for earth ground If the power source does not provide a ground connection consult an electrici...

Страница 25: ...lights Alrm indicator goes off Health and Status screen no longer displays a No Signal message If connecting the DSU to a LADS network there are distance limitations that govern the use of DSUs on th...

Страница 26: ...e switched 56 kbps network connection 495 14860 Switched 56 kbps Network Connection Backup POW ER LINE BACKUP CC DC V 35 SJA56 or SJA48 Wall Jack ISDN DBM Network Connection The 2 wire ISDN DBM has an...

Отзывы: