Specifications
Criteria
AC POWER FUSE
Model 3610/3611 DSU
3000 Series Carrier
No accessible fuse
4-amp fuse, Paradyne part number 190-0037-0431
(two spares supplied with carrier)
AC POWER REQUIREMENTS
3610 DSU
3610 DSU with DBM
3611 DSU
3611 DSU with DBM
DBM (V.32 or Switched 56)
3000 Series Carrier (16 DSUs with DBMs
plus SDU and fan module)
24 Vac (CT), 60 Hz +3 (0.093 amp, 5.8 watts at 115 Vac)
24 Vac (CT), 60 Hz +3 (0.114 amp, 9.5 watts at 115 Vac)
24 Vac (CT), 60 Hz +3 (0.029 amp, 4.5 watts at 115 Vac)
24 Vac (CT), 60 Hz +3 (0.080 amp, 8.0 watts at 115 Vac)
24 Vac (CT), 60 Hz +3 (0.024 amp, 2.0 watts at 115 Vac)
90 —132 Vac, 60 Hz +3 (1.650 amp, 165 watts at 115 Vac)