14
5.
Secure the other end of the Telco 50-pin cable by tightening the captive pan-head
screw.
6.
If a ferrite choke is included with your T1 or E1 card, install it on the cable as close
as possible to the chassis. If the choke fits loosely on the cable, hold it in place with
a cable tie.
Fastening a Cable with Locking Pivot Brackets
Procedure
To fasten a Telco connector to the chassis with locking pivot brackets:
1.
Replace the longer captive screw on the cable connector with the #4-40 Phillips
pan-head screw shipped in a plastic bag with the BLC.
2.
Install the locking pivot bracket onto the cable end of the connector using the
captive screw, as illustrated below.
3.
Locate the connector on the back of the chassis that corresponds with the slot
where you installed the T1 or E1 card. Connectors are labeled 2 and 3 on the 8620
BLC, and 1–18 on the 8820 BLC.
Locking Pivot
Bracket
Captive #4-40 Phillips-Head Screw
(Part of Locking Pivot Bracket)
Customer-Supplied
Cable with Connector
Replace with a shorter
Captive Screw provided
with the Pivot Bracket
99-16162a-02
Locking Pivot
Bracket
Содержание 8995
Страница 23: ...23...
Страница 24: ...24 8990 A2 GN10 20 8990 A2 GN10 20...