Technical Specifications
Table 4. Technical Specifications
Specifications
Criteria
Approvals
Safety Certifications
Refer to the equipment’s label for approvals on product.
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
–40
°
to 149
°
F (–40
°
to 65
°
C)
–40
°
F to 158
°
F (–40
°
C to 70
°
C)
5% to 95% (noncondensing)
Withstands normal shipping and handling.
POTS Interface
Signaling
Transmission
Dialing
Loops
Loop-start, single party POTS service per GR-506
GR-507
DTMF and pulse dialing per GR-506
1500 Ohms
Power
48V power is distributed through the BAC chassis
backplane.
Power Dissipation
Idle: 17.7 W
6 lines off-hook: 24.9 W
24 lines off-hook: 46.3 W
Size
Length: 10.4 inches (26.42 cm)
Height: 11.15 inches (28.32 cm)
Width: 1.0 inches (2.54 cm)
Test Access
2-wire and 4-wire integrated MTAU per GR-818
MTAU TL1 command support per GR-834
Voice Processing
Encoding
Echo Cancellation
VoATM Protocol
G.711 (64 kbps PCM), G.726 (32 kbps ADPCM)
G.168
LES CAS per af-vmoa-145.001
Weight
Approximately 1.7 lbs. (0.77 kg)