Standards Compliance for SNMP Traps
B-4
7970-A2-GB20-00
August 1999
There are no variable-bindings for enterpriseDeviceFail, enterprisePrimary
ClockFail, enterpriseSecondaryClockFail, enterprisePrimaryClockFailClear,
enterpriseSecondaryClockFailClear, and enterpriseConfigChange. The
variable-binding for enterpriseSelfTestFail is devSelfTestResults.
The following list describes the conditions that define enterpriseFallbackAutoRate
and enterpriseFallbackAutoRateClear:
enterpriseFallbackAutoRate Variable-Bindings
H
ifIndex (RFC 1573)
This object provides the index into the ifTable and potentially into tables in other MIBs.
The values of ifIndex are the same for all models, although not all indexes are
supported for each model.
The ifIndex included with the trap consists of:
– 1
COM Port
– 2
M/xDSL Interface
– 6
G.703 Interface
H
ifAdminStatus (RFC 1573)
This object specifies the operational state of the interface:
– up(1)
M/xDSL Network: DSL link is established.
G.703: No alarm condition exists.
– down(2)
M/xDSL Network: DSL link is not established.
G.703: An alarm condition exists.
– testing(3)
A test is active on the interface.
H
ifOperStatus (RFC 1573)
This object contains the same value as ifAdminStatus.
H
i
fType (RFC 1573)
This object is the type of interface:
– e1(19)
Used for the G.703 E1 interface.
Содержание 7984
Страница 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Страница 44: ...Initial Startup and Configuration 3 16 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Страница 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Страница 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Страница 154: ...Cables and Pin Assignments C 14 7970 A2 GB20 00 August 1999 This page intentionally left blank ...
Страница 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999 ...