Configuration Option Tables
A-21
7610-A2-GB20-10
November 1997
Table A-8.
Alarms & Traps Options (2 of 2)
SNMP Trap Disconnect
Possible Settings: Enable, Disable
Default Setting: Enable
Determines if a Management port external device connection is dropped after sending
an SNMP trap.
A call established to send out an ASCII alarm always disconnects automatically if
the call was initiated automatically.
Enable – The external device disconnects after sending out an SNMP trap.
Disable – The external device remains connected and must be disconnected by remote
modem or manually. This allows the NMS to poll the DSU after receiving an SNMP trap.
Call Retry
Possible Settings: Enable, Disable
Default Setting: Disable
Specify if an unsuccessful call is retried.
Enable – The call is retried up to five times for each ASCII alarm and each SNMP trap.
The following options, Dial-Out Delay Time (min) and Alternate Dial-Out Directory,
affect the amount of time before a retry and the number of retries.
Disable – No retry of an unsuccessful call.
Dial-Out Delay Time (min)
Possible Settings: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
Default Setting: 5
This delay applies to both the number of minutes before a new call is initiated for a
different alarm and the number of minutes between call retries. Refer to the previous
option,
Call Retry
.
1 to 10 – Number of minutes before a call is initiated or retried.
Alternate Dial-Out Directory
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies whether an incomplete call initiated for an ASCII alarm or SNMP trap is
attempted using the Alternate Directory phone number.
Both Alarm & Trap Dial-Out and Call Retry options must be enabled.
Enable – After attempting to reach the Primary Directory phone number five times, the
alternate dial-out directory phone number is dialed five times.
NOTE:
The Alternate Directory phone number is dialed. Refer to the
Call Setup
section of Chapter 3.
Disable – No alternate phone number is used.